Cluster hub — angular contact ball bearings

Angular Contact Ball Bearings: the 72 and 73 Metric Series

An angular-contact ball bearing takes axial load in one direction only: its single contact angle means the load path closes through one shoulder of the ring set. That is why the family so often runs in pairs — and why the dimension series, which sets the section the pair must fit, is the first decision. At the same 20 mm bore this evidence set publishes 47 × 14 mm at Cr 17.6 kN and 52 × 15 mm at Cr 21.7 kN: two envelopes, one bore code. This hub compares the published designations of both series at equal bore and states plainly where the evidence is thin.

01 — Overview: what this cluster covers

The raceways of an angular-contact ball bearing are offset so that the balls contact them at an angle to the radial plane. Radial load produces a force component along the axis; axial load in one direction is carried cleanly, in the other direction not at all. Spindles, lead screws and pump thrust ends use the family precisely for this one-way stiffness — mounted singly against a shoulder or in paired sets for two-direction location and preload.

This hub is built only from designations that have a published, model-bound manufacturer record — 39 records covering 39 designations across 2 dimension series. Every dimension and rating below is read from those records at build time; where a series has no published record at a bore, the page shows the gap instead of filling it.

Scope & supply

Evidence scope: every specification on this hub is a manufacturer-published catalogue value (Koyo/JTEKT product-detail pages), reproduced per designation with its source named on the model page. Supply scope: the sitewide model combines source-factory production through cooperating-factory capacity for confirmed core bearing lines with consolidated sourcing and delivery for complementary requirements. No owner-approved family-level supply route is currently recorded for this page. A manufacturer attribution identifies the source of product data; it does not identify the manufacturer or source that will fulfil a specific order. A catalogue listing does not establish own production, current stock or availability. Confirm the actual manufacturer, original designation, order supply route, batch and quantity (if stock is offered), lead time, MOQ and applicable quality documents in the quotation.

Quick selection rule

Decide the envelope before the rating. The series digit fixes the outside diameter and width the housing and the mating shoulder must take; the bore code then only picks the shaft size inside that section. The B suffix on these records marks the contact-angle execution — it is part of what the drawing must state, because the angle is what the stiffness and the one-way axial behaviour come from.

Coverage of this hub, by dimension series (published records only)
SeriesPublished designationsBore range (mm)Manufacturer sources
72 21 10–100 Koyo / JTEKT
73 18 17–100 Koyo / JTEKT

02 — Specifications

Values are reproduced per designation as published by the manufacturer source. Boundary dimensions are in millimetres: d is the bore, D the outside diameter, B the width. Cr is the basic dynamic radial rating and C0r the basic static rating in kN. A dash means the field is not on that record — it is not zero and it is not "typical".

72 series — published records
DesignationdDBCr kNC0r kNSource
7200 10309 6.752.75 Koyo / JTEKT spec page
7201 123210 104.05 Koyo / JTEKT spec page
7202 153511 10.14.25 Koyo / JTEKT spec page
7203 174012 12.75.5 Koyo / JTEKT spec page
7204B 204714 17.68.4 Koyo / JTEKT spec page
7205B 255215 18.49.4 Koyo / JTEKT spec page
7206B 306216 25.613.6 Koyo / JTEKT spec page
7207B 357217 33.818.5 Koyo / JTEKT spec page
7208B 408018 40.223 Koyo / JTEKT spec page
7209B 458519 45.126.1 Koyo / JTEKT spec page
7210B 509020 46.728.6 Koyo / JTEKT spec page
7211B 5510021 57.736.2 Koyo / JTEKT spec page
7212B 6011022 69.944.6 Koyo / JTEKT spec page
7213B 6512023 79.552.6 Koyo / JTEKT spec page
7214B 7012524 86.457.8 Koyo / JTEKT spec page
7215B 7513025 93.663.3 Koyo / JTEKT spec page
7216B 8014026 10169.3 Koyo / JTEKT spec page
7217B 8515028 11681.1 Koyo / JTEKT spec page
7218B 9016030 13393.8 Koyo / JTEKT spec page
7219B 9517032 145101 Koyo / JTEKT spec page
7220B 10018034 163115 Koyo / JTEKT spec page
73 series — published records
DesignationdDBCr kNC0r kNSource
7303B 174714 18.58.1 Koyo / JTEKT spec page
7304B 205215 21.79.65 Koyo / JTEKT spec page
7305B 256217 30.514.6 Koyo / JTEKT spec page
7306B 307219 36.619 Koyo / JTEKT spec page
7307B 358021 45.824.3 Koyo / JTEKT spec page
7308B 409023 5630.3 Koyo / JTEKT spec page
7309B 4510025 6737.2 Koyo / JTEKT spec page
7310B 5011027 85.348.3 Koyo / JTEKT spec page
7311B 5512029 98.456.7 Koyo / JTEKT spec page
7312B 6013031 11365.8 Koyo / JTEKT spec page
7313B 6514033 12775.6 Koyo / JTEKT spec page
7314B 7015035 14386 Koyo / JTEKT spec page
7315B 7516037 15697.3 Koyo / JTEKT spec page
7316B 8017039 169109 Koyo / JTEKT spec page
7317B 8518041 182122 Koyo / JTEKT spec page
7318B 9019043 195135 Koyo / JTEKT spec page
7319B 9520045 209149 Koyo / JTEKT spec page
7320B 10021547 238178 Koyo / JTEKT spec page

How to check a stated parameter

  • d, D, B, Cr, C0r — each value on a specification page carries its source class and a link to the manufacturer product-detail page it was read from. Click through from a row above and read the source line on that page.
  • Abutment diameters and chamfers — where a record publishes them they appear on that designation's spec page; where it does not, the field reads as not published rather than being derived here.
  • Limiting speed — a catalogue limiting speed under a stated lubrication, not an application operating speed; your lubrication, load and mounting decide the usable figure.
  • Contact angle / suffix — the suffix (B on these records) is part of the ordered designation. Read it from the marking on delivery; a same-size bearing with a different contact-angle suffix is a different stiffness, not an equivalent.

03 — Selection & applications

(a) At equal bore, the series digit is the decision

These are bores where this evidence set publishes more than one series. Each table is generated from the published records — nothing is interpolated between them:

Equal bore 20 mm — published values, series comparison
DesignationSeriesDBCr kNC0r kN
7204B 72 471417.68.4
7304B 73 521521.79.65
Equal bore 25 mm — published values, series comparison
DesignationSeriesDBCr kNC0r kN
7205B 72 521518.49.4
7305B 73 621730.514.6
Equal bore 40 mm — published values, series comparison
DesignationSeriesDBCr kNC0r kN
7208B 72 801840.223
7308B 73 90235630.3

The pattern the evidence supports: the heavier section consistently publishes the higher rating at an equal bore and buys it with outside diameter and width. At the 25 mm bore the gap between the two published series is 10 mm of outside diameter for roughly sixty percent more Cr — a housing decision made before any load calculation matters.

(b) One contact angle means one axial direction

Every record this hub carries is a single-contact-angle execution. Such a bearing reacts axial force in one direction only; a shaft that must be located both ways needs a second bearing facing the other way — a paired mount — or a different family for the opposite end. This is the practical difference between this family and the deep-groove ball bearing of the same bore: a deep-groove execution locates both ways alone at lower axial stiffness. The choice is not "which is better" but "how the shaft is held".

(c) Where this evidence set is thin — and what that means

The coverage table shows bore gaps inside both series (for example, no published record at a few mid-range bores). Absence of a designation from this page means no evidence record exists for it here, not that it is unavailable. Paired-set matching (universal-match grind codes, preload classes) is a per-order property no catalogue table in this evidence set carries — it is confirmed at quotation, from the marking and the order documents, never inferred from the series.

(d) Which pair arrangement — and what changes with each?

Once a second bearing is required, the orientation of the pair becomes its own decision. NSK's matched angular-contact page (fetched 2026-11-15) names the three arrangements and what each trades: back-to-back (DB) — the distance between the effective load centres a0 is large, so this type is suitable if moments are applied; face-to-face (DF) — radial and axial loads in both directions are sustained, but compared with the DB type the effective load-centre distance is small, so the capacity to sustain moments is inferior to DB; tandem (DT) — loads in one direction only, "used when the load in one direction is heavy", the two bearings sharing that single-direction axial load. DB and DF react axial load both ways; DT does not.

The contact angle the same source describes as a speed-versus-thrust trade: larger contact angles offer greater capacity for axial loads, while smaller contact angles are better for high-speed rotation — the 30° (A) and 40° (B) executions this hub publishes sit on that trade. NSK adds that a preload is often used to increase the rigidity of single-row angular contact ball bearings, particularly in machine-tool main spindles where running accuracy is crucial, and that matched sets are manufactured and supplied as a set — dimension series 70, 72 and 73, bore diameters 10 to 200 mm, to be mounted together to deliver the higher rigidity or combined capacity the arrangement was selected for. That is why the set arrives matched and marked as a pair, not as two independently selected singles.

(e) Exact matched-pair example: Koyo 7205BDB pressed cage vs 7205BDB FY machined cage

JTEKT lists both designations as factory matched, back-to-back (DB) angular-contact pairs with a pressed or machined cage respectively. They share the same 25 × 52 × 30 mm envelope and the same published mounting dimensions, but their load ratings and lubrication-specific limiting speeds differ. This is a real ordering choice within one mounting envelope — not a generic claim that one cage is always better.

JTEKT exact product records — matched DB pairs
Buyer check7205BDB7205BDB FY
Factory configurationMatched pair, back-to-back (DB), pressed cageMatched pair, back-to-back (DB), machined cage
Boundary dimensions d × D × B25 × 52 × 30 mm25 × 52 × 30 mm
Basic dynamic load rating Cr29.9 kN28.4 kN
Basic static load rating C0r18.8 kN17.4 kN
Fatigue load limit Cu1.15 kN1.05 kN
Limiting speed — grease lubrication7,300 min⁻¹9,200 min⁻¹
Limiting speed — oil lubrication9,600 min⁻¹12,000 min⁻¹
Load-centre spread a47.7 mm47.7 mm
Mounting da(min.) / Db(max.)30.5 / 47.5 mm30.5 / 47.5 mm
Shoulder fillets ra(max.) / rb(max.)1.0 / 0.6 mm1.0 / 0.6 mm
Reference mass0.270 kg0.270 kg

How to read the trade: the machined-cage 7205BDB FY has higher catalogue limiting speeds (9,200 vs 7,300 min⁻¹ on grease; 12,000 vs 9,600 min⁻¹ on oil), while the pressed-cage 7205BDB has higher published Cr, C0r and Cu. Select against the actual load, lubrication and operating-speed point; do not choose by cage label or speed alone. These are catalogue limiting speeds, not guaranteed continuous operating speeds.

Fit and ordering boundary: both records publish da(min.) = 30.5 mm, Db(max.) = 47.5 mm, ra(max.) = 1 mm and rb(max.) = 0.6 mm. The 30 mm width is the matched pair's combined envelope. Do not treat 7205BDB as two independently ordered 7205B singles, double a single-bearing rating, or infer the actual preload/axial-clearance class: the public product records do not state a numeric preload or axial-clearance value. Confirm the full designation, pair marking, preload/clearance and order documents at quotation.

Manufacturer records: JTEKT 7205BDB — pressed cage; JTEKT 7205BDB FY — machined cage. Ratings, limiting speeds, dimensions and mounting values are transcribed from each exact product record.

How much axial load does this family need to keep the balls rolling?

This is a family with a published load-ratio floor, not just a capacity ceiling. SKF's design-considerations page for single-row angular contact ball bearings states the requirement per execution: an axial-to-radial load ratio of Fa/Fr ≥ 1 is required by bearings in the 70 B, 72 B(E) and 73 B(E) series, and Fa/Fr ≥ 0.55 by the 72 AC and 73 AC series — and "if the load ratio requirement is not met in each case, bearing service life can be reduced" (source: skf.com single-row angular contact design considerations page, fetched 2026-11-15). The reason is the same one-way geometry this page describes in section (b): when the axial load acts predominantly in one direction in a back-to-back or face-to-face pair, the axially unloaded bearing of the pair experiences unfavourable rolling conditions for its balls — SKF names the consequences as increased noise levels, discontinuity in the lubricant film, and increased stresses on the cage. Under those circumstances SKF recommends zero operating clearance, attained by using springs; where springs are not sufficient, a 25°-contact-angle bearing used as a backup bearing may help.

The buyer decision this produces: before choosing a lighter or smaller-angle execution to "save" the pair, check which direction the heavy axial load points and whether the second bearing of the pair stays loaded. A purely radial application is a signal to re-read the deep-groove comparison in section (b), not to under-load an angular-contact pair.

What happens when the pair's clearance or preload is set wrong — either way?

SKF's design-considerations page frames the adjustment window from both sides. Single-row angular contact bearings "must be adjusted against each other until the requisite clearance or preload is obtained"; the failure modes are symmetric and opposite: "if there is too much clearance in the bearing arrangement during operation, the load carrying capacity of the bearings will not be fully utilized", while "excessive preload produces more friction and higher operating temperatures, leading to a reduction in bearing service life" (source: skf.com single-row angular contact design considerations page, fetched 2026-11-15). The page also states the escape from per-machine adjustment: universally matchable bearings "mounted immediately adjacent to each other require no further adjustment" — their requisite clearance or preload is obtained by choosing bearings from an appropriate clearance or preload class and applying suitable fits on the shaft and in the housing. SKF puts the stakes plainly: performance and operational reliability depend on proper adjustment for single bearings and on the correct clearance/preload selection for universally matchable ones.

For ordering, this is why the matched-set question in the RFQ list below asks for the class explicitly: the class and the fits together are what deliver the preload at assembly, and neither is inferable from the dimension tables in section 02.

When is this family worth it over a deep-groove ball of the same bore?

Not on catalogue rating alone. At the same boundary dimensions an angular contact execution carries more balls and higher capacities than the deep-groove ball bearing, "suitable for higher loads and speeds with proper lubrication" — but the same geometry buys the capacity with one-way thrust, pairing discipline and tighter assembly (source: amroll.com angular contact page, collected copy without a publish date). The failure-mode framing is the sharper buyer test: deep groove is the default "unless axial load or stiffness is driving the failure mode — if you're seeing heat, noise, or early fatigue from axial thrust, it's usually time to evaluate angular contact (often as a matched pair)", and the upgrade wins on high thrust or thrust reversals with pairing, high moment loads in DB, and precision axial location; it is a poor fit when misalignment is expected and no self-aligning feature exists, when assembly capability cannot control preload, fits and thermal growth, or when cost sensitivity is high and loads are mostly radial (source: harronbearing.com deep-groove-vs-angular-contact comparison, April 10, 2026). One nuance the same-size comparison adds: the limit speed of an angular contact ball bearing of one size runs higher than that of the deep-groove ball bearing of that size (source: wzzgbearing.com deep-groove vs angular contact resource, April 19, 2023) — so speed is rarely the reason to stay on deep groove; assembly discipline is. The verdict this page draws: pay for this family only when thrust, stiffness or axial positioning is the binding requirement — never for a radial-only duty that a quality deep-groove execution already serves.

Which contact angle — and what does overspecing it cost at speed?

The angle is a bid, not a safety margin. The published trade is monotone: larger contact angles offer greater axial-load capacity, smaller angles are better for high-speed rotation (NSK, cited in section (d)); the 15° execution is the high-speed/low-thrust choice, 25° the balanced speed-and-thrust class for precision duty, 40° the heavy-axial class at moderate speed (source: harronbearing.com angular contact types and contact angle guide, April 8, 2026). The supplier-side default confirms where most duty lands: unless the end-user specifies otherwise, 40° ("B" suffix) is what ships, in vertical motors, pumps and thrust applications; the suffix code maps A = 30°, B = 40°, C = 15°, AC = 25° (source: amroll.com angular contact page, collected copy without a publish date). The buyer boundary is heat, not capacity: buyers who "overspec a 40° angle to be safe, then struggle with heat at speed" are the recurring failure the source names — its rule is to start with the lowest contact angle that meets thrust and stiffness targets, then reach rigidity through arrangement and preload without spending the speed margin (same harronbearing.com source). Never buy the angle from the axial-load column alone unless the speed check at your operating point passes first; a shaft whose duty is small, frequent thrust at high rpm belongs on the smaller angle with a pair, not on the biggest angle in the table.

Can one half of a matched pair be replaced on its own?

Never as a like-for-like repair. Universally ground or set-matched pairs carry controlled ring stand-out differences that establish the preload; mixing a new single bearing into a run-in pair destroys that match — "preload becomes unknown, usually too light" — so pairs are replaced as sets of the same suffix and preload class, or the arrangement is re-shimmed with measured values (source: mpnbase.com DB/DF/DT and preload guide, September 24, 2026). The same discipline extends the rest of the order: keep the angle and preload class when substituting — a 40° "B" pair dropped in for a 25° "A5"-class pair changes thrust capacity, heat and stiffness all at once; respect the orientation marks, because mounting a ring reversed turns a DB arrangement into a DF arrangement and changes the moment stiffness; and cross-brand substitution is a verify-grade exercise even when the envelope matches — compare the preload/stand-out catalogue values, not just the bore code (same mpnbase.com source). The supply-side semantics back this: flush-ground ("G") bearings are ground to "no axial clearance, no preload" and sold individually, so any two randomly selected "G" bearings can be mounted together as a pair, while preloaded bearings are packaged in pairs to a declared class — light (GA), medium (GB), heavy (GC) under ISO specs, or fixed force classes such as G02 = 20 lb / 90 N under USA specs (source: amroll.com angular contact page, collected copy without a publish date). When you quote, the grind code and the class are order-line properties: state which of the two supply forms you hold before ordering a single unit into an existing pair.

Why does a single-direction, pure-axial duty not select this family?

Because this family's geometry is paid for with combined load, and a pure axial duty pays without using it. The bearing taxonomy sorts families by force direction, and a load applied in the same direction as the shaft — pure axial — maps to the thrust-ball-bearing category, not to the radial ball families (source: wzzgbearing.com deep-groove vs angular contact resource, April 19, 2023). The angular contact execution cannot cover the role unaided either: with no flange on one side of the outer race it supports thrust in one direction only, and even in tandem (DT) a third thrust-capable bearing must be employed elsewhere on the shaft to locate it in the opposite direction (source: amroll.com angular contact page, collected copy without a publish date); a single angular contact bearing is also unstable under pure radial load — it is built to push along a sloped contact line, and the second bearing completes the load loop (source: mpnbase.com DB/DF/DT and preload guide, September 24, 2026). If the thrust reverses, this family needs a paired mount; if the thrust never reverses and radial load is absent or trivial, the thrust-ball family carries that duty more directly, and an angular contact pair only adds preload, fits and orientation constraints the duty never asked for. Choose this family when radial and axial arrive together — fails if the load is one-directional pure axial and the shaft end just needs a thrust face.

How much preload is right — and what fails at either end?

Preload fails in both directions, by different mechanisms. Too little: balls left unloaded in the light zone skid and smear the raceway. Too much: the pair runs hot and life shortens non-linearly — and because micrometres of ring stand-out decide which side of that line a pair lands on, matched sets are ground to a controlled stand-out so that clamping the faces produces a defined preload class (source: mpnbase.com DB/DF/DT and preload guide, September 24, 2026). The class itself is a duty selection, not a quality ladder: light preload for high-speed spindles where low heat matters and external loads are modest; medium for general machine tools and gear-shaft locations; heavy for stiff, low-speed precision positions — where "heat and grease-life penalties rise fast" (same source). Section (f) covers the adjustment window SKF publishes (too much clearance leaves capacity unused; excessive preload raises friction and temperature); this page's complement to it is the skid mechanism on the light end and the class-choice rule: pick the lightest class that kills skid at your operating point, never the heaviest class on offer unless the duty is slow and stiffness-bound, and treat running preload — after thermal growth — as the number that matters, since a pair correct at room temperature can be over-preloaded at operating temperature (source: harronbearing.com angular contact types and contact angle guide, April 8, 2026).

Which duty maps to which execution — and is there a double-row shortcut?

The published duty recommendations pair the angle with the arrangement, not with capacity alone. High-speed spindle duty selects the 15° execution (25° when the thrust component runs higher) mounted as single-row DB pairs with controlled preload; heavy-thrust duty selects 40° in DT when the thrust is one-directional or in DB when it reverses — and the speed limit for that exact size must be validated before the order, not assumed from the family's general speed reputation; compact bidirectional thrust selects the 25–40° double-row execution instead of building the pair from two singles (source: harronbearing.com duty recommendations table, April 8, 2026; ledger S1/f08). The double-row route is not a convenience footnote: DB/DF combinations and the double-row execution both carry axial load in both directions, while DT only suits larger one-directional axial load — so where housing space cannot host a wide DB pair, the double-row execution keeps the bidirectional function without the spread (Koyo-derived block, ledger S3/f13). For the top of the speed range the same block names a dedicated execution: ACH-type high-speed executions — small, numerous balls — are mostly for machine tool spindles (ledger S3/f13). Never let the arrangement choice silently delete the speed check: a heavy-thrust 40° order that skips the per-size speed validation fails the duty it was chosen for, and a compact-duty buyer who cannot host DB should price the double-row execution before forcing a narrow pair into the housing.

What does the preload-class code on your order line actually force?

Two code systems exist, and naming the wrong one on an RFQ does not order the preload you validated. Under ISO specs the classes are GA light, GB medium, GC heavy; under USA specs the classes carry fixed published forces: G02 = 20 lb / 90 N, G05 = 50 lb / 222 N, G100 = 100 lb / 445 N, G200 = 200 lb / 890 N, G500 = 500 lb / 2224 N (source: amroll.com angular contact page suffix list, collected copy without a publish date; ledger S5/f03). The buyer decision is precision of language, not brand preference: state the code system on the order line, because "light" is not a force and a G-code without its system is not a class. Treat the fixed-force values as the published ladder, and confirm the exact force your supplier binds to the code for the size and brand you are buying — the class-to-force binding is an order-line property, cannot be inferred from the dimension tables in section 02, and a pair delivered one class off fails at exactly the ends section (k) describes: skid on the light side, heat and shortened life on the heavy side. Never accept a quotation that names neither a code system nor a class.

04 — Quality & verification

Every supplier claims catalogue conformance. The question that separates them is what document ties the delivered bearing to the published numbers.

How a buyer verifies each stated parameter

Stated on this pageWhat it rests onWhat you should hold to verify it
d, D, B boundary dimensionsA manufacturer product-detail record, reproduced per designation with its sourceMeasure the delivered bearing against the invoice designation — boundary dimensions are checkable with a caliper and no instruments beyond it
Cr / C0r basic ratingsThe same record, as published for that designationA certificate of conformity naming the designation and the rating basis; the certificate's job is to tie the delivered unit to the designation
Limiting speedCatalogue limiting speed under a stated lubricationNot a deliverable property — verify through your own thermal and speed validation, not a supplier document
Contact-angle suffixThe designation as markedThe marking on the delivered ring; for paired sets, the match/grind code on both boxes, not one
DB / DF / DT arrangement propertiesNSK matched angular-contact page, fetched 2026-11-15: DB large effective load-centre distance (moment-suitable), DF smaller (moment capacity inferior to DB), DT single-direction heavy axial load shared by both bearingsThe arrangement suffix on the set marking (example forms: 7208 A DB / 7208 B DF / 7208 A DT); both boxes of a matched set, not one
Contact-angle trade (30° vs 40°)NSK angular-contact overview, fetched 2026-11-15: larger angles greater axial capacity, smaller angles better high-speed rotationThe angle suffix on the delivered ring plus your own speed/axial-split calculation — the trade is the manufacturer's statement, where your load lands is your analysis
Matched-set supply (series 70/72/73, bores 10–200 mm)NSK matched angular-contact page, fetched 2026-11-15: manufactured and supplied as a set to be mounted togetherSet-level marking and packing documents proving the two units were ground and matched as one set — not two separate order lines
Load-ratio floor (Fa/Fr ≥ 1 for the 70 B / 72 B(E) / 73 B(E) series; ≥ 0.55 for the 72 AC / 73 AC series) and the unloaded-bearing failure signs (noise, lubricant-film discontinuity, cage stress)The manufacturer design-considerations page for single-row angular contact ball bearings (skf.com, fetched 2026-11-15)Your own load split at the operating point: axial and radial components per bearing of the pair — design arithmetic you re-run, not a delivered-part property
Adjustment window (too much clearance: capacity not fully utilized; excessive preload: more friction, higher temperatures, reduced service life) and universal matching via clearance/preload class + fitsThe same manufacturer design-considerations page (skf.com, fetched 2026-11-15)The set's class/marking documents plus your fits drawing — confirmed against the class the set was made to, before assembly, not inferred from the dimension table
Manufacturer source (JTEKT)The record's provenance, named per model pageWhat the source names is the catalogue basis of the numbers — it is not a statement about who manufactured the unit you receive; confirm the actual manufacturer and its marking at order

What this page cannot verify

  • It cannot verify a supplier's "equivalent to" claim. Without a designation, a rating basis and a test method, "equivalent" is marketing. Ask for the designation and the conformity document.
  • It cannot verify preload class or pair-matching. Those are grind and selection properties set at manufacture and marked on the set; a dimension table cannot carry them, and a hub cannot substitute for the set documents.
  • It cannot verify a batch. Ratings are catalogue values; whether a delivered lot met them is what a certificate of conformity and, where required, dimensional or hardness checks establish.
  • It cannot verify the achieved stiffness. Preload, fit and mounting decide the stiffness your assembly gets; the catalogue angle is the starting point, not the result.
  • It cannot verify which arrangement your loads need. The DB/DF/DT moment and direction properties are the manufacturer's general statements; whether moments act on your pair, and in which direction the heavy axial load points, comes from your loading diagram, not from this page.
  • It cannot verify which bearing of your pair is the unloaded one. The load-ratio floor and its failure signs are published family behaviour; which bearing sits at the light end, whether springs are a workable remedy, and the actual Fa/Fr at your operating point are your arrangement's arithmetic — check it against the floor before commissioning, not after noise appears.

06 — SKU specification library

Only designations with a published model page are listed. Each page carries the full field set that record publishes, with its sources.

07 — Buyer questions

Questions that arrive with a designation and an order quantity, and the answer this hub can stand behind.

Can I use a 7305B where the drawing says 7205B?
Only if the housing has the room. Both take the same 25 mm shaft, but the heavier section publishes 62 × 17 mm against 52 × 15 mm — 10 mm more outside diameter and 2 mm more width — and Cr 30.5 against 18.4 kN. A housing bored for the light section will not close over the heavy one. The rating gain is worthless if it does not fit; the fit failure is discovered at mounting, not at quotation, unless the envelope is checked first.
Why does my assembly need two of these where one deep-groove bearing worked?
Because a single-contact-angle bearing reacts axial load in one direction only. Where the old deep-groove execution located the shaft both ways by itself, the angular-contact pair splits the job: one bearing each way. That is also where its higher axial stiffness comes from — not from a bigger catalogue number.
The drawing says "7204 B" with a space — is that one designation?
Yes: the B is the contact-angle suffix, part of the ordered designation. Do not let quoting drop it — the same size without the suffix can be a different angle execution with a different stiffness and axial behaviour.
Why do some bores not appear in the tables?
Because this hub lists only designations with a published manufacturer record. A missing bore means the evidence set is thin there, not that the size is unavailable. Supply for unlisted designations is confirmed at quotation.
Are these JTEKT bearings?
The sources are: each record on this hub was read from the manufacturer's own product-detail page (named per model page), and those pages are the basis of every number. What you receive is confirmed at quotation — the published figures define the designation's catalogue values, not the manufacturing origin of a specific quoted lot.
Should my pair be DB or DF?
NSK's arrangement descriptions (fetched 2026-11-15) give the deciding property: back-to-back (DB) has the larger distance between effective load centres, so it suits applications where moments are applied; face-to-face (DF) sustains loads both ways too but with the smaller load-centre distance its moment capacity is inferior to DB; tandem (DT) takes one direction only, for heavy one-way axial loads shared across both bearings. Both react axial load in both directions; DT does not — so if your shaft must be located both ways, DT alone is not the arrangement.
Is 40° always better than 30° for thrust?
It carries more of it — NSK states larger contact angles offer greater axial capacity, smaller ones better high-speed rotation — but "better" depends on which limit binds your application. If your bearing is speed-limited, the smaller angle's high-speed advantage can matter more than the larger angle's thrust capacity; the angle suffix on the designation you order fixes the trade, so it is chosen against your own load split and speed, not in the abstract.
Our pair is mostly radial — is that a problem for this family?
Check it against the published load-ratio floor before ordering. The manufacturer states per-execution requirements: Fa/Fr ≥ 1 for the 70 B, 72 B(E) and 73 B(E) series, ≥ 0.55 for the 72 AC and 73 AC series, with reduced service life when the requirement is not met. When the axial load is predominantly one-directional in a DB or DF pair, the unloaded bearing of the pair shows it first — the manufacturer names increased noise, breaks in the lubricant film and higher cage stresses as the signs — and recommends zero operating clearance via springs, or a 25°-contact-angle backup bearing where springs are not enough (source: skf.com single-row angular contact design considerations page, fetched 2026-11-15). A mostly radial duty is a signal to reconsider the deep-groove comparison in section (b), not to under-load this family.
Do we have to adjust the pair's preload on the machine, or is the set ready to mount?
Depends on what you order, and the trade-off is published. Single bearings — and non-universal sets — must be adjusted against each other until the requisite clearance or preload is reached; too much clearance leaves the load capacity unused, excessive preload raises friction and temperature and shortens life. Universally matchable bearings mounted adjacent to each other need no further adjustment: the preload comes from the clearance or preload class the set was made to, together with the fits you apply on the shaft and in the housing (source: skf.com single-row angular contact design considerations page, fetched 2026-11-15). Either way, the class is a set-document fact — send it with the RFQ rather than expecting it to appear in a dimension table.

08 — Request a quotation

An angular-contact quote goes wrong in three ways this hub exists to prevent: a suffix dropped from the designation, a series swapped into a housing that cannot take it, and a pair ordered without its set documents. Send these and we can answer on the first pass.

  • Full designation as marked — series, bore code and contact-angle suffix; set/match codes if the order is a matched pair or set.
  • Quantity — pieces or sets; annual volume if known.
  • Housing envelope: available outside diameter and width, so a series substitution can be assessed.
  • Load case: radial and axial loads, the axial direction(s), speed, and whether the bearing runs singly or in a pair.
  • Preload requirement if your assembly specifies one — quoted from the set documents, not inferred.
  • Documents required: certificate of conformity and any dimensional or hardness checks your inspection will run.
  • Destination and required delivery date.

Send the details for a quotation