Deep Groove Ball Bearings
Deep groove ball bearing 6305
Deep groove ball bearing 6305, open, boundary dimensions 25 mm × 62 mm × 17 mm. Specifications below are model-bound published values; the source class is identified for each parameter. Send your application details through the RFQ for a confirmed quotation.
Last updated: 2026-11
Specifications
| Specification | Value | Parameter class | Source publisher |
|---|---|---|---|
| Bore diameter (d) | 25 mm | Model designation & boundary dimension | jtekt.co.jpManufacturer-published specification |
| Outside diameter (D) | 62 mm | Model designation & boundary dimension | jtekt.co.jpManufacturer-published specification |
| Width (B) | 17 mm | Model designation & boundary dimension | jtekt.co.jpManufacturer-published specification |
| Basic dynamic load rating (Cr) | 25.7 kN Basic dynamic load rating is a catalog reference used in bearing-life calculations; confirm equivalent load, speed, reliability and required service life for the application. | Manufacturer catalog reference — not a supply guarantee | jtekt.co.jpManufacturer-published specification |
| Basic static load rating (C0r) | 11.3 kN Basic static load rating is a catalog reference; verify equivalent static load and the required static safety factor for the application. | Manufacturer catalog reference — not a supply guarantee | jtekt.co.jpManufacturer-published specification |
| Limiting speed, grease lubrication | 11000 min-1 Catalog limiting speed for grease lubrication, not an application operating recommendation. Confirm lubricant, temperature, load, sealing and duty conditions before selection. | Manufacturer catalog reference — not a supply guarantee | jtekt.co.jpManufacturer-published specification |
| Limiting speed, oil lubrication | 13000 min-1 Catalog limiting speed for oil lubrication, not an application operating recommendation. Confirm lubricant, temperature, load, sealing and duty conditions before selection. | Manufacturer catalog reference — not a supply guarantee | jtekt.co.jpManufacturer-published specification |
| Shaft abutment diameter (da min.) | 31.5 mm | Model designation & boundary dimension | jtekt.co.jpManufacturer-published specification |
| Housing abutment diameter (Da max.) | 55.5 mm | Model designation & boundary dimension | jtekt.co.jpManufacturer-published specification |
| Fillet radius (r max.) | 1 mm | Model designation & boundary dimension | jtekt.co.jpManufacturer-published specification |
| Reference mass | 0.232 kg | Manufacturer catalog reference — not a supply guarantee | jtekt.co.jpManufacturer-published specification |
Parameter classes: Model designation & boundary dimension — what identifies the model (boundary dimensions follow the designation). Manufacturer catalog reference — the named manufacturer's published catalog data for this designation; it is not a guarantee that every unit we supply reaches these exact figures. Industry reference — a third-party or industry-published value; it is not specific to the named manufacturer and is not a supply guarantee. Supplier-confirmed — a value we have confirmed for our own supply. Order-confirmed — the value fixed in a specific order. None of the values on this page are supplier-confirmed yet; supply-specific figures (tolerance class, clearance, seal variant availability, lead time) are confirmed with your quotation.
The source publisher shown on each row identifies where that parameter was published; it is not necessarily the manufacturer supplying your order. Manufacturer-published specifications are linked where the source is approved for public linking. Industry-reference publishers are shown as text.
All values above are model-bound catalog values traceable to a collected source. Fields without collected evidence are not published; ask with your inquiry and we confirm them at quotation.
Manufacturer / model attribution: Koyo / JTEKT — 6305 (open). This is the manufacturer named by the model-evidence record; it does not establish that every item supplied for an inquiry comes from this manufacturer. The actual manufacturer, original model and supplying source are confirmed in the quotation.
Source per specification field
| Specification | Source |
|---|---|
| Bore diameter (d) | jtekt.co.jp — manufacturer-published specification |
| Outside diameter (D) | jtekt.co.jp — manufacturer-published specification |
| Width (B) | jtekt.co.jp — manufacturer-published specification |
| Basic dynamic load rating (Cr) | jtekt.co.jp — manufacturer-published specification |
| Basic static load rating (C0r) | jtekt.co.jp — manufacturer-published specification |
| Limiting speed, grease lubrication | jtekt.co.jp — manufacturer-published specification |
| Limiting speed, oil lubrication | jtekt.co.jp — manufacturer-published specification |
| Shaft abutment diameter (da min.) | jtekt.co.jp — manufacturer-published specification |
| Housing abutment diameter (Da max.) | jtekt.co.jp — manufacturer-published specification |
| Fillet radius (r max.) | jtekt.co.jp — manufacturer-published specification |
| Reference mass | jtekt.co.jp — manufacturer-published specification |
6305 variants — 2 published executions
The 6305 designation fixes the boundary dimensions. The published executions below share the same base designation and verified manufacturer attribution. Each row retains its own source-record configuration; choose only after checking the manufacturer, sealing arrangement and lubrication requirements.
| Model | Manufacturer record | Source configuration | Bore d (mm) | Outside D (mm) | Width B (mm) | Execution | Cr (kN) |
|---|---|---|---|---|---|---|---|
| 6305 | Koyo / JTEKT | open | 25 mm | 62 mm | 17 mm | open | 25.7 kN |
| 6305 ZZ | Koyo / JTEKT | double metal shield | 25 mm | 62 mm | 17 mm | ZZ shielded | 25.7 kN |
Every row identifies the manufacturer and configuration from that exact variant's evidence record. Parameter cells are that page's own model-bound catalog values; unpublished fields are not shown. A manufacturer record is not a promise of the order's supplying source. Click a column header to sort. If you need an execution not listed here, send it in the inquiry and we confirm availability at quotation.
6305 vs 6304 vs 6304 ZZ vs 6304 2RS — same-manufacturer series comparison
Nearest published designations in the same series. A manufacturer is named only when the evidence record identifies a bearing maker; otherwise the column says it is not identified. Source configuration and each field's publisher attribution remain separate. When more than one manufacturer appears, this is a cross-manufacturer catalog comparison, not an equivalence, interchangeability or common-source claim. Highlighted rows are the parameters that differ across these published records; unhighlighted rows have identical published values, not necessarily identical performance in service.
| Parameter | 6305 (this page) Manufacturer: Koyo / JTEKT Source configuration: open | 6304 Manufacturer: Koyo / JTEKT Source configuration: open | 6304 ZZ Manufacturer: Koyo / JTEKT Source configuration: double metal shield | 6304 2RS Manufacturer: Koyo / JTEKT Source configuration: double contact seal |
|---|---|---|---|---|
| Bore diameter (d) | 25 mm standard-model · jtekt.co.jp · Manufacturer-published specification | 20 mm standard-model · koyo.jtekt.co.jp · Manufacturer-published specification | 20 mm standard-model · koyo.jtekt.co.jp · Manufacturer-published specification | 20 mm standard-model · koyo.jtekt.co.jp · Manufacturer-published specification |
| Outside diameter (D) | 62 mm standard-model · jtekt.co.jp · Manufacturer-published specification | 52 mm standard-model · koyo.jtekt.co.jp · Manufacturer-published specification | 52 mm standard-model · koyo.jtekt.co.jp · Manufacturer-published specification | 52 mm standard-model · koyo.jtekt.co.jp · Manufacturer-published specification |
| Width (B) | 17 mm standard-model · jtekt.co.jp · Manufacturer-published specification | 15 mm standard-model · koyo.jtekt.co.jp · Manufacturer-published specification | 15 mm standard-model · koyo.jtekt.co.jp · Manufacturer-published specification | 15 mm standard-model · koyo.jtekt.co.jp · Manufacturer-published specification |
| Basic dynamic load rating (Cr) | 25.7 kN reference-manufacturer · jtekt.co.jp · Manufacturer-published specification · Basic dynamic load rating is a catalog reference used in bearing-life calculations; confirm equivalent load, speed, reliability and required service life for the application. | 19.9 kN reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Basic dynamic load rating is a catalog reference used in bearing-life calculations; confirm equivalent load, speed, reliability and required service life for the application. | 19.9 kN reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Basic dynamic load rating is a catalog reference used in bearing-life calculations; confirm equivalent load, speed, reliability and required service life for the application. | 19.9 kN reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Basic dynamic load rating is a catalog reference used in bearing-life calculations; confirm equivalent load, speed, reliability and required service life for the application. |
| Basic static load rating (C0r) | 11.3 kN reference-manufacturer · jtekt.co.jp · Manufacturer-published specification · Basic static load rating is a catalog reference; verify equivalent static load and the required static safety factor for the application. | 7.85 kN reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Basic static load rating is a catalog reference; verify equivalent static load and the required static safety factor for the application. | 7.85 kN reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Basic static load rating is a catalog reference; verify equivalent static load and the required static safety factor for the application. | 7.85 kN reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Basic static load rating is a catalog reference; verify equivalent static load and the required static safety factor for the application. |
| Fatigue load limit (Cu) | — not published Not published for this designation | 0.66 kN reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Fatigue load limit is a catalog reference, not a standalone allowable-load or service-life guarantee; verify application duty and lubrication conditions. | 0.66 kN reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Fatigue load limit is a catalog reference, not a standalone allowable-load or service-life guarantee; verify application duty and lubrication conditions. | 0.66 kN reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Fatigue load limit is a catalog reference, not a standalone allowable-load or service-life guarantee; verify application duty and lubrication conditions. |
| Limiting speed, grease | 11000 min-1 reference-manufacturer · jtekt.co.jp · Manufacturer-published specification · Catalog limiting speed for grease lubrication, not an application operating recommendation. Confirm lubricant, temperature, load, sealing and duty conditions before selection. | 14000 min-1 reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Catalog limiting speed for grease lubrication, not an application operating recommendation. Confirm lubricant, temperature, load, sealing and duty conditions before selection. | 14000 min-1 reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Catalog limiting speed for grease lubrication, not an application operating recommendation. Confirm lubricant, temperature, load, sealing and duty conditions before selection. | 9500 min-1 reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Catalog limiting speed for grease lubrication, not an application operating recommendation. Confirm lubricant, temperature, load, sealing and duty conditions before selection. |
| Limiting speed, oil | 13000 min-1 reference-manufacturer · jtekt.co.jp · Manufacturer-published specification · Catalog limiting speed for oil lubrication, not an application operating recommendation. Confirm lubricant, temperature, load, sealing and duty conditions before selection. | 17000 min-1 reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Catalog limiting speed for oil lubrication, not an application operating recommendation. Confirm lubricant, temperature, load, sealing and duty conditions before selection. | Not published for this designation | Not published for this designation |
Each published cell carries its own parameter tier and publisher attribution; each column identifies the manufacturer only when the evidence record names one, plus the source configuration. A source publisher is not necessarily the supplying source for an order. Cross-manufacturer values are shown for catalog context only: they do not establish interchangeability, equivalent quality, common manufacturing origin or a preferred supply route. Compare values only within the stated parameter class, publisher, configuration and operating conditions. Industry-reference values are not manufacturer-specific. Confirm fit, load, speed, clearance, sealing and actual supplying source for your application in the quotation.
SKF 6305 — double shield (2Z) versus double contact seal (2RS1)
SKF publishes the 6305 in both double-shielded and double-contact-sealed executions. The nominal envelope and basic load ratings are the same, but the closure changes the contamination barrier and the published limiting speed. Choose by the expected contaminant exposure and speed duty, not by the shared 6305 base number alone.
| Buyer check | SKF 6305-2Z | SKF 6305-2RS1 |
|---|---|---|
| Boundary dimensions (d × D × B) | 25 × 62 × 17 mm | 25 × 62 × 17 mm |
| Basic dynamic load rating (C) | 23.4 kN | 23.4 kN |
| Basic static load rating (C₀) | 11.6 kN | 11.6 kN |
| Closure execution | Shield on both sides; non-contact | Seal on both sides; contact |
| Factory-filled lubricant | Grease | Grease (standard catalogue execution) |
| Limiting speed | 13,000 r/min | 7,500 r/min |
| SKF performance class | Explorer | Explorer (catalogue family table) |
The SKF speed table gives 13,000 r/min for 6305-2Z and 7,500 r/min for 6305-2RS1. The 2Z shield is non-contact and therefore has the higher published limiting speed; the 2RS1 contact seal provides a stronger closure against contaminants but its contact friction lowers the listed speed limit. These are catalogue limits, not a guaranteed continuous operating speed: load, temperature, lubrication, fit, cage and cooling conditions still need to be checked.
This comparison does not assign a quantified water-ingress rating or dust-protection class, and does not establish the grease type, fill quantity, seal material or order-specific clearance. Confirm the complete suffix and manufacturer on the quotation; do not treat 6305-2Z and 6305-2RS1 as interchangeable just because their basic dimensions and load ratings match.
Sources: SKF official 6305-2Z product page (dimensions, load ratings, non-contact shields and grease); SKF official 6305-2RS1 product listing (contact seals on both sides and grease); SKF Rolling Bearings in Electric Motors and Generators, speed-rating table for 6300 series, printed page 356 (6305-2Z and 6305-2RS1 rows; common C/C₀ and limiting speeds).
SKF 6305 — radial internal clearance before mounting
SKF lists 6305-2Z with Normal (CN) radial internal clearance and separately lists 6305/C3 with C3 clearance. For the 25 mm bore range (over 24 mm through 30 mm), SKF's deep-groove-ball-bearing clearance table gives the following limits:
| Clearance group | Radial internal clearance | Difference from Normal |
|---|---|---|
| C2 | 1–11 μm | Below Normal |
| Normal (CN / C0) | 5–20 μm | Standard group |
| C3 | 13–28 μm | Above Normal |
| C4 | 23–41 μm | Above C3 |
| C5 | 30–53 μm | Above C4 |
Buyer selection boundary: C3 is not automatically “better” than Normal. SKF says clearance selection depends on speed, operating temperature, shaft fits and axial-movement limits; interference fits and operating temperature can reduce the clearance after mounting. Check the required residual/operating clearance for the actual shaft, housing and thermal condition before specifying C3.
The tabulated values are for an unmounted bearing under zero measuring load and conform to ISO 5753-1991 for the catalogued size range. They are not a post-mounting measurement, an operating-clearance guarantee or proof that every sealed execution is available in every clearance group. Confirm the complete SKF suffix and availability on the order.
Sources: SKF official 6305/C3 product page (25 × 62 × 17 mm and C3 designation); SKF official 6305-2Z product page (Normal/CN clearance); SKF SKF Bearings and Mounted Products, Deep groove ball bearings, “Internal clearance”, Table 1, printed page 37, row 24–30 mm (C2, Normal, C3, C4 and C5 limits; zero measuring load).
6305 (25 mm bore) — CM motor clearance is not CN or C3
Buyer conclusion: if a motor-bearing RFQ specifies CM for a 6305-size deep-groove ball bearing, do not approve an ordinary CN or C3 bearing as an automatic substitute. The independently published NSK, Koyo / JTEKT and Schaeffler tables agree on a tighter CM interval of 5–12 μm for a 25 mm bore, but CM is a separate motor-bearing clearance designation rather than another name for CN or C3.
| Clearance group for d = 25 mm | Initial radial clearance | What the interval means for substitution |
|---|---|---|
| CM — electric-motor bearing | 5–12 μm | Narrower upper limit; do not replace with a generic CN declaration without a measured/guaranteed CM range |
| CN / Normal | 5–20 μm | Shares the CM lower limit but permits up to 8 μm more clearance at the upper limit |
| C3 | 13–28 μm | Starts 1 μm above the CM maximum in the published tables; it is not a CM equivalent |
Cross-source finding: NSK Table 8.14.1, JTEKT Table 10-7 and Schaeffler TPI 165 Table 6 all publish CM = 5–12 μm for the bore interval 18 mm < d ≤ 30 mm. For the same 24 mm < d ≤ 30 mm interval, their Normal/CN limits are 5–20 μm and C3 limits are 13–28 μm. Schaeffler explicitly describes CM as a tighter-tolerance clearance for 10–50 mm bore bearings, particularly suitable for electric motors; its suffix table defines CM as a narrower tolerance than Normal and lists availability by agreement. This supports the numeric comparison, not blanket cross-brand interchangeability.
Receiving-inspection trap: the 5–12 μm CM interval is the theoretical clearance before mounting, not the raw feeler-gauge reading under measuring load. NSK and JTEKT both state that for d = 25 mm the measurement-load correction is 5 μm at 49 N. Therefore, under that stated measurement condition, the corresponding measured window is 10–17 μm (theoretical limit + 5 μm). A measured value of 10–12 μm is not automatically “too large” for CM; it must be corrected using the stated load before comparison. Do not apply the 49 N correction to a different measuring load or method.
NSK's motor-bearing table also pairs the 18–30 mm CM range with a recommended shaft fit of k5 and housing-bore fits H6/H7 or JS6/JS7, with the housing choice depending on whether the outer ring must move axially. These are catalogue recommendations, not a substitute for the actual shaft/housing drawing and operating-clearance calculation. Interference, temperature difference and load can change residual and operating clearance after assembly.
Scope: this comparison uses the 25 mm nominal bore of the 6305 size and the manufacturers' general deep-groove-ball / electric-motor clearance tables. It does not prove that every 6305 seal, cage, precision class or grease execution is offered in CM, nor that an NSK, JTEKT or Schaeffler bearing is otherwise interchangeable. Confirm the exact manufacturer, complete designation, CM marking, measurement load, shaft/housing fits, seal, cage, grease and batch inspection record on the quotation. The 1 μm CM-to-C3 interval gap is a catalogue-table boundary, not a statement about unreported manufacturing capability or measurement uncertainty.
Sources: NSK Rolling Bearings for Industrial Machinery, catalogue E1103C, Table 8.14.1 (printed p. A170; CM 5–12 μm for 18–30 mm and recommended fits), Table 8.10 and clearance-correction table (printed p. A169; CN 5–20 μm, C3 13–28 μm and 49 N / 5 μm correction for 18–50 mm); NSK catalogue PDF. Koyo / JTEKT Ball & Roller Bearings, CAT. NO. BS004EN-2DS, Table 10-7 (printed pp. A104–A105; CM 5–12 μm for 18–30 mm) and Table 10-2 clearance-correction table (printed pp. A102–A103; 49 N / 5 μm correction); JTEKT catalogue PDF. Schaeffler Deep groove ball bearings Generation C, TPI 165, issue 01 / October 2026, Section 11.1, printed p. 18, Tables 5 and 6 (CN/C3 and CM limits; CM suitable for electric motors and values without measurement-load deformation); Schaeffler TPI 165. ISO 5753-1:2009, Edition 1, 2009-10, confirmed current in 2021; the standard classification is the reference cited by Schaeffler for the Group 2 / N / 3 / 4 clearance table; ISO standard record.
6305 P5 — ISO Class 5 is not a universal ABEC 5 suffix equivalence
Buyer conclusion: when a quotation specifies a 6305 P5 deep-groove ball bearing, write the governing precision standard explicitly. Do not accept “P5 = ABEC 5” as a universal code conversion. NSK's 2024 designation guide defines its P5 suffix as ISO 492 Class 5, while it separately defines PA5 as AFBMA 5. An older NSK machine-tool spindle guide cross-references P5 with ABEC 5, but that guide is specifically about machine-tool spindle precision bearings; its crosswalk should not be generalized to every standard radial bearing.
| Evidence / designation | What the source actually says | Safe buyer interpretation |
|---|---|---|
| NSK 2024 designation guide — P5 | P5 tolerance class as per ISO 492 | For NSK code interpretation, P5 identifies the ISO class 5 route |
| NSK 2024 designation guide — PA5 | Tolerance class as per AFBMA 5 | Do not silently rewrite PA5 as P5; the manufacturer's own code table distinguishes them |
| NSK machine-tool spindle guide | Its spindle-bearing precision-grade table cross-references P5 with ABEC 5 and ISO Class 5 | Useful within that guide's spindle-bearing context, not proof that every 6305 P5 offer is certified to ABEC 5 |
| NSK exact 6305P5 product record | 25 × 62 × 17 mm, open type, CN radial clearance, tolerance P5 | The product record confirms P5 and CN as separate attributes; it does not label the part PA5 or publish a batch measurement certificate |
What P5 controls — and what it does not: ISO 492 covers specified dimensional and geometrical characteristics of radial bearings. In SKF's P5 table, the 6305 size falls in the 18–30 mm bore row and 50–80 mm outside-diameter row: the inner-ring mean bore deviation is 0/−6 μm with Kia maximum 4 μm; the outer-ring mean outside-diameter deviation is 0/−9 μm with Kea maximum 8 μm. These are SKF's published class-table limits used here as an ISO-class reference, not measurements of an NSK bearing and not an order-batch certificate.
Important execution boundary: SKF's same P5 table states that no outer-ring tolerance values have been established there for capped (sealed or shielded) bearings. Therefore, do not copy the open-bearing outer-ring P5 table values onto a 6305 ZZ or 6305 2RS execution without the manufacturer's applicable drawing or written tolerance specification. Likewise, P5 does not define radial internal clearance: NSK's exact 6305P5 record separately states CN clearance. P5 alone does not establish cage, seal, grease, load rating, shaft/housing fit, or operating runout after mounting.
RFQ and receiving-inspection fields: request the complete bearing designation and manufacturer; whether the requirement is ISO 492 Class 5 or ABMA/AFBMA ABEC 5; the standard edition; open / ZZ / 2RS execution; the required ring dimensional deviations and runout characteristics; and the manufacturer's inspection record or agreed acceptance method. If the application depends on assembled spindle runout, specify shaft and housing runout separately rather than treating the bearing's P5 class as the complete spindle accuracy.
Scope and limits: the exact NSK 6305P5 record is an open, CN, 25 × 62 × 17 mm deep-groove ball bearing. The SKF numerical values are taken from its 2018 general P5 tolerance table and are not represented as NSK-specific values. The NSK machine-tool crosswalk applies to the precision spindle-bearing guide's product context; the 2024 NSK designation table is the more specific source for distinguishing NSK P5 from PA5 suffix meaning. The 2023 ISO 492 edition is the current standard record cited here; the 2018 SKF numerical table is not claimed to be a clause-by-clause reproduction of every revision in ISO 492:2023.
Sources: NSK Bearing Designation Systems, BD 03 / 2024, Section 3.9, Table 3.9, printed p. 34 (P5 = ISO 492; PA5 = AFBMA 5), and Section 4, printed p. 43 (code comparison); NSK designation guide PDF. NSK Machine Tool Spindle Bearing Selection & Mounting Guide, “Precision Grades”, printed p. 17 (P5 / ABEC 5 / ISO Class 5 crosswalk; spindle-bearing context); NSK spindle guide PDF. NSK official 6305P5 product record (dimensions, open execution, CN and P5; accessed 2026-11-25). SKF Rolling bearings, PUB BU/P1 17000/1 EN, October 2018, Section A.2, Table 1 printed p. 36 and Table 4 printed p. 40 (P5 class and 6305-size inner/outer ring limits); SKF catalogue PDF. ISO 492:2023, Edition 6, August 2023, Clause 1 and 6.2.3, Tables 8–9 (radial-bearing scope and Class 5); ISO 492:2023 official record.
SKF 6305-2Z — shaft and housing abutment limits
SKF publishes the following mounting-interface dimensions for the exact 6305-2Z execution. They help check whether the shaft shoulder, housing shoulder and their corner radii clear the bearing rings; use these limits rather than assuming that every 6305 manufacturer's drawing is identical.
| Interface dimension | SKF 6305-2Z limit | What to check |
|---|---|---|
| Shaft abutment diameter (dₐ) | min. 32 mm; max. 36.5 mm | Shoulder must support the inner ring without exceeding the published shoulder envelope |
| Housing abutment diameter (Dₐ) | max. 55 mm | Housing shoulder must not extend beyond the permitted outer-ring abutment diameter |
| Shaft / housing fillet radius (rₐ) | max. 1 mm | Mating corner radius must clear the bearing corner |
| Bearing chamfer (r₁,₂) | min. 1.1 mm | SKF's minimum bearing corner dimension; do not treat it as the shaft or housing fillet radius |
Drawing-screening rule: keep the shaft abutment diameter within 32–36.5 mm, the housing abutment diameter at or below 55 mm, and the mating fillet radius at or below 1 mm for this SKF 6305-2Z reference. The bearing corner dimension is r₁,₂ min. 1.1 mm. Check the actual shoulder-face width and support geometry in the assembly drawing before release.
These are abutment and corner-clearance dimensions, not shaft-seat or housing-bore fit tolerances, shoulder-face runout limits, or a complete machining drawing. They apply to the cited SKF 6305-2Z product data and must not be copied to another manufacturer or suffix without checking that product's drawing.
Source: SKF official 6305-2Z product page (Dimensions and Abutment dimensions: dₐ min. 32 mm / max. 36.5 mm; Dₐ max. 55 mm; rₐ max. 1 mm; r₁,₂ min. 1.1 mm).
6305 seal choice — dust, water, friction and grease retention are separate trade-offs
Buyer conclusion: do not treat a contact seal as universally “better” than a metal shield, or treat ZZ, LLB, LLU, 2Z and 2RS as interchangeable names. For the NTN 6305 test conditions, its LLU contact seal gave the strongest dust-test score, but also materially higher friction torque than ZZ and LLB. NTN also reports the greatest grease leakage trend for LLU at 1,800 r/min and attributes it to temperature rise. A buyer therefore needs to choose against the actual contaminant and duty: dry dust, water splash, speed/heat and grease-loss tolerance are different requirements.
| Evidence for NTN 6305 | ZZ metal shield | LLB non-contact rubber seal | LLU contact rubber seal |
|---|---|---|---|
| Construction | Metal shield with labyrinth clearance | Rubber seal edge with labyrinth clearance | Rubber lip contacts the inner-ring V-groove; second lip forms a small gap |
| Friction torque, 1,800 r/min / 29 N radial / 20 min | Low; plotted about 20–30 N·mm | Low; plotted about 20–30 N·mm | Higher; plotted about 70–80 N·mm |
| Dust test average score | 2.25 | 2.62 | 3.00 |
| Grease leakage at 1,800 r/min | Below LLU in NTN's chart | Below LLU in NTN's chart | Highest trend in NTN's chart; NTN attributes this to temperature rise |
The dust score is ordinal, not a percentage: NTN defines 3 as “complete absence of dust”, 2 as “slight presence”, and 1 as “presence clearly observed”. The averages 2.25 / 2.62 / 3.00 therefore must not be converted into percentage improvements or a general service-life ratio. Test conditions were NTN 6305, Alvania grease S3, 3.5 g fill, 1,800 r/min, 29 N radial load, 40-litre test chamber, oxidized ferrous powder mixture, and one hour. Friction/temperature was measured for 20 minutes on five pieces per type. Grease leakage was measured for 200 hours at 80 °C ambient and 1,800 / 600 r/min, five pieces per type.
Do not over-transfer the water test: NTN's muddy-water splash test used 6304, not 6305. Under that separate 6304 test, LLB averaged 1.6 and LLU 2.8 on a four-point penetration scale, but those values are not 6305 results and are not a cross-manufacturer comparison. For 6305 water exposure, the reviewed evidence supports only the structural/qualitative guidance below; a 6305-specific water-ingress result remains unverified.
What the independent manufacturer guidance adds
- SKF: its capping-device matrix rates shields highly for low friction and high speed but only fair for grease retention and dust exclusion, and “not recommended” for static, dynamic and high-pressure water exclusion. Contact seals score strongly for grease retention and dust exclusion; water protection differs by static, dynamic and high-pressure exposure. SKF explicitly says the matrix cannot replace testing the seal in the application.
- JTEKT / Koyo: its manufacturer comparison likewise describes ZZ as low-friction and high-speed, while 2RS contact sealing has higher friction and a speed limitation. It distinguishes the water/dust performance of its own 2RU, 2RS, 2RK and 2RD constructions; its note says the published comparison is for standard types and may change with grease and seal material.
- NTN: its LLU is not simply a generic “2RS”. The inner lip contacts the V-groove while an outer lip sits across a small gap; NTN describes the outer lip moving closer as the inner lip wears. That is an NTN-specific double-lip design, not proof that another maker's contact seal has the same wear response.
Practical selection and RFQ boundary
- For relatively clean service where low torque and speed dominate, a shield or non-contact execution may be the better starting candidate; do not assume it is suitable for direct water, washdown or high-pressure spray.
- For dry dust where a metal shield is insufficient but contact friction is undesirable, ask whether the exact manufacturer offers a non-contact rubber labyrinth execution (for example NTN LLB or the relevant SKF non-contact/low-friction design). Do not translate those suffixes into a universal cross-brand equivalence.
- For water splash or washdown, specify the exposure type and seek an exact contact-seal or higher-protection execution with a matching application test. A generic “2RS” request does not define lip profile, rubber compound, static/dynamic water protection or high-pressure capability.
- Ask for the full manufacturer designation, seal cross-section/drawing, seal material, grease type and fill quantity, allowed temperature, seal torque or test method, speed/load/duty conditions, and the test report for the exact 6305 execution. Record whether the inner or outer ring rotates; SKF says shields are primarily intended for inner-ring rotation and warns that outer-ring rotation can cause grease leakage at high speed.
- At receiving, verify manufacturer and full suffix against the approved drawing and quotation. Visual presence of a rubber seal or a “2RS” marking alone does not prove equivalent ingress protection or torque.
Scope and limits: the numerical performance test is NTN's own 6305 test under its stated conditions, not a test of SKF or JTEKT bearings. The water-splash test is on NTN 6304 and is explicitly excluded from 6305 conclusions. SKF and JTEKT provide independent qualitative selection guidance, not a common test protocol. No matched cross-brand 6305 dust/water/torque/grease-leakage test, exact order-level seal drawing, seal compound, or application-specific ingress approval was found. This section does not approve a 6305 substitute or establish a universal superiority ranking.
Sources: NTN, Ball Bearings — Shield and Seal Types, CAT. No. 3015-5/E, copyright 2025, Table 1 “Bearing design and features” (printed p.3); friction torque/temperature rise, grease leakage and dust tests, Figs. 1–2 and Table 2 (printed p.4); muddy-water splash test, Table 3 (printed p.4, 6304 only): NTN catalogue PDF. JTEKT / Koyo, FAQ “シールド及びシール付き玉軸受の性能比較について教えてください” (shield/seal performance comparison table; standard-type caveat; accessed 2026-11-25): JTEKT FAQ. SKF, Rolling bearings, PUB BU/P1 17000/1 EN, October 2018, Deep groove ball bearings, Table 1 “Selection guidelines for SKF capping devices”, printed p.242; shield design/inner-ring rotation notes, printed pp.242–243: SKF catalogue PDF.
6305 ZZ — JTEKT / Koyo versus NSK mounting-interface comparison
Both manufacturers publish a double-shielded 6305 ZZ with the same 25 × 62 × 17 mm envelope and the same maximum housing abutment diameter and corner radius. Their published shaft-shoulder upper limits differ, so a shaft drawing that clears one manufacturer's stated range is not automatically within the other's range.
| Published item | JTEKT / Koyo 6305 ZZ | NSK 6305ZZ |
|---|---|---|
| Boundary dimensions (d × D × B) | 25 × 62 × 17 mm | 25 × 62 × 17 mm |
| Shaft abutment diameter (dₐ) | 31.5–34 mm | 31.5–36 mm |
| Housing abutment diameter (Dₐ max.) | 55.5 mm | 55.5 mm |
| Corner radius (rₐ max.) | 1 mm | 1 mm |
| Minimum bearing chamfer (r min.) | 1.1 mm | 1.1 mm |
| Basic dynamic / static radial load rating | Cr 25.7 kN / C₀r 11.3 kN | Cr 22.6 kN / C₀r 11.2 kN |
| Grease limiting speed | 11,000 min⁻¹ | 13,000 min⁻¹ |
| Reference mass | 0.232 kg | approx. 0.235 kg |
Drawing-screening consequence: a shaft shoulder diameter greater than 34 mm and up to 36 mm is within the cited NSK 6305ZZ published interval, but exceeds the cited JTEKT / Koyo 6305 ZZ maximum. If the shaft shoulder is 31.5–34 mm, both cited product pages cover that interval. Do not treat the 36 mm NSK upper limit as permission to use that geometry with JTEKT / Koyo 6305 ZZ.
The load ratings and grease limiting speeds are manufacturer-published values for each exact execution, not a controlled test under identical conditions and not permissible working-load or guaranteed continuous-speed limits. Cr and C₀r are basic rating inputs; actual selection still depends on equivalent load, required life, lubrication, temperature, fit and duty cycle. The shared 6305 ZZ suffix does not make manufacturer data or physical products interchangeable without checking the actual source and drawing.
These are abutment and corner-clearance dimensions, not shaft-seat fit tolerances, housing-bore tolerances, shoulder-face width, axial locating capacity or a complete machining drawing. The comparison applies only to the cited JTEKT / Koyo 6305 ZZ and NSK 6305ZZ product pages; do not transfer it to 6305 open, 6305 2RS, NR variants, other manufacturers or other precision / clearance suffixes.
Sources: JTEKT / Koyo official 6305 ZZ product detail (Specification data and Mounting dimensions: dₐ min. 31.5 mm / max. 34 mm, Dₐ max. 55.5 mm, rₐ max. 1 mm; Cr, C₀r and grease limiting speed); NSK official 6305ZZ Series product page (Boundary Dimensions, Basic Load Ratings, Speeds and Abutment and Fillet Dimensions: dₐ 31.5–36 mm, Dₐ max. 55.5 mm, rₐ max. 1 mm; Cr 22,600 N, C₀r 11,200 N, grease speed 13,000 min⁻¹).
6305 — cross-manufacturer speed ratings need their own operating conditions
Buyer conclusion: do not treat a 6305 suffix or one catalogue RPM figure as a universal continuous operating speed. The published values depend on whether the bearing is open, double shielded or double contact sealed, and manufacturers do not all publish the same kind of speed limit. In particular, SKF's 24,000 r/min reference speed is a thermal reference value, not permission to run a 6305 continuously at 24,000 r/min.
| Manufacturer source / 6305 execution | Open | Double shield | Double contact seal | What the number means |
|---|---|---|---|---|
| NSK — Electric Motor Handbook (2024) | 13,000 grease; 16,000 oil-bath | 13,000 grease (ZZ/Z) | 8,000 grease (DDU/DU) | Empirical grease / conventional oil-bath limiting speeds |
| JTEKT / Koyo — exact 6305 product records | 11,000 grease; 13,000 oil-bath | 11,000 grease (ZZ) | 7,500 grease (2RS) | Product-table limiting speeds, with load and speed-advisory conditions in the catalogue |
| SKF — Bearing Handbook for Electric Motors | 16,000 limiting; 24,000 reference | 13,000 limiting (2Z) | 7,500 limiting (double sealed) | Limiting speed is mechanical; reference speed is thermal |
These are manufacturer-published catalogue values, not results from a common comparative test. NSK's handbook explicitly labels grease and conventional oil-bath columns. JTEKT's exact product records likewise separate grease and oil-bath values for the open bearing, while its ZZ and 2RS records publish grease values. SKF's electric-motor handbook instead labels the table as mechanical limiting speed and thermal reference speed; it does not make its 16,000 r/min open-bearing limit a grease-only or oil-bath-only figure. Therefore the open-bearing numbers cannot be ranked as though all three manufacturers tested the same lubrication regime.
The closure comparison is more directly aligned but still not a suffix equivalence: the cited double-contact-sealed values cluster at 7,500–8,000 r/min, while the double-shield values are 11,000–13,000 r/min. This supports the practical conclusion that contact-seal friction is a meaningful speed constraint, but it does not prove identical seal geometry, rubber compound, grease fill, or contamination performance. A 6305 ZZ / 2Z is not a drop-in substitute for a 6305 2RS / 2RS1 / DDU when the machine relies on contact sealing.
Why the catalogue limits cannot be used as a direct pass/fail number
- NSK normal-load envelope: the Electric Motor Handbook says its grease and oil limiting speeds apply to standard-design bearings under approximately C/P ≥ 12 and Fa/Fr ≤ 0.2. Above 70% of the listed speed, NSK calls for a grease or oil with good high-speed characteristics.
- JTEKT normal-load envelope: CAT. NO. BS004EN-2DS, Section 8, uses approximately C/P ≥ 16 and Fa/Fr ≤ 0.25. Above 80% of the catalogue speed, JTEKT says to consult it. If C/P falls below 16 or Fa/Fr exceeds 0.25, its method calls for a corrected limit nₐ = f₁ × f₂ × n; the uncorrected table value is not the final answer for that load case.
- SKF speed meanings: Publication 140-430 separates reference speed (thermal conditions) from limiting speed (mechanical limits), says both are cautionary rather than strict prohibitions, and notes that limiting speed typically determines the maximum for capped bearings. Its reference speed must not be read as a higher mechanical operating limit.
- JTEKT contact-seal mechanism: Section 8-2 says the limiting speed of contact-sealed ball bearings is governed by rubbing speed where the seal contacts the inner ring; its standard NBR contact seal uses a 15 m/s rubbing-speed reference. The cited material does not provide the exact seal contact diameter for this 6305 execution, so do not convert 15 m/s into an RPM figure using the bearing pitch diameter.
Threshold illustration, not an approved operating speed: for the JTEKT 6305 ZZ grease limit of 11,000 r/min, 80% is 8,800 r/min; for NSK 6305 ZZ at 13,000 r/min, 70% is 9,100 r/min. At 9,000 r/min, the JTEKT advisory threshold has already been crossed, while the NSK 70% lubricant-selection threshold has not quite been crossed. This does not certify the NSK bearing for 9,000 r/min: its normal-load assumptions, lubricant, temperature, clearance, fit and heat rejection still have to be satisfied. The different trigger points are manufacturer-specific guidance, not a universal safety factor.
For a sealed 6305, the same arithmetic gives a JTEKT 2RS consultation threshold of 6,000 r/min (80% × 7,500) and an NSK DDU/DU high-speed-lubricant threshold of 5,600 r/min (70% × 8,000). These calculated thresholds are derived from the manufacturers' published values and advisory percentages; they are not separately published ratings and do not replace the load correction or thermal assessment.
RFQ / replacement checks: state the exact manufacturer and complete suffix; continuous and peak speed; grease or oil-bath / circulating-oil method; lubricant grade and fill quantity; radial and axial load (so C/P and Fa/Fr can be checked); bearing and ambient temperatures; clearance, cage, fits and cooling / heat-dissipation arrangement. If the duty approaches the manufacturer's advisory threshold, request written confirmation for the actual load, lubricant and assembly rather than accepting the catalogue RPM alone.
Scope: 6305 standard single-row deep-groove ball bearings only, using the exact NSK 6305 handbook row, JTEKT 6305 / 6305 ZZ / 6305 2RS product records, and SKF 6305 series speed row. NSK DDU/DU, JTEKT 2RS and SKF double-sealed entries are functional closure categories for this comparison, not proof of identical seal designs or interchangeable part numbers. The SKF reference-speed figure is not compared with the NSK/JTEKT grease limiting-speed columns. No application-specific safe speed, grease life, bearing temperature or batch performance is established here.
Sources: NSK Electric Motor Handbook — Reference Guide to Bearing Selection and Handling, publication code EMHB V1 / ACAT / 24 (2024), “Speed Ratings Definitions & Overview” printed p.8 and “Limiting Speeds — Deep Groove Ball Bearings, 6300 Series” printed p.12 (6305: open 13,000 / 16,000 grease / oil; ZZ/Z 13,000 grease; DDU/DU 8,000 grease; C/P and Fa/Fr conditions; 70% advice); JTEKT Ball & Roller Bearings, CAT. NO. BS004EN-2DS, Section 8 “Limiting speed” printed pp. A84–A85 (C/P ≥ 16, Fa/Fr ≤ 0.25, 80% consultation, correction nₐ = f₁ × f₂ × n); official 6305 open, 6305 ZZ and 6305 2RS product records (25 × 62 × 17 mm; 11,000 / 13,000, 11,000 and 7,500 min⁻¹ respectively); SKF Bearing Handbook for Electric Motors, Publication 140-430 (2M 11/2020), “Speed limitations” printed p.7 and “Speed ratings” printed p.8, Table 6300 series (6305 double sealed 7,500, double shielded 13,000, open 16,000, reference 24,000 min⁻¹); ISO 15312:2018, Edition 2, 2018-02, abstract and reference-condition scope (thermal speed rating; oil-bath calculation and reference grease conditions).
6305 ZZ / 2Z — dynamic and static load ratings answer different replacement questions
Buyer conclusion: do not choose a 6305 ZZ / 2Z replacement by comparing only Cr or only C₀r. The three cited manufacturers publish the same 25 × 62 × 17 mm envelope and double-sided non-contact shield execution, but the rating order changes with the load question: JTEKT publishes the highest basic dynamic radial rating, while SKF publishes the highest basic static radial rating. Neither ranking alone approves a replacement.
| Manufacturer / exact designation | Shield execution | Cr / C (kN) | C₀r / C₀ (kN) | Additional published rating field |
|---|---|---|---|---|
| Koyo / JTEKT 6305 ZZ | Double-sided shield (ZZ) | 25.7 | 11.3 | Cu = 0.860 kN; f₀ = 13.2 |
| NSK 6305ZZ | Double-sided shield (ZZ) | 22.6 | 11.2 | f₀ = 13.2 |
| SKF 6305-2Z | Double-sided non-contact shield (2Z) | 23.4 | 11.6 | Pu = 0.49 kN; f₀ = 12; SKF Explorer |
Cross-source result: the published dynamic-rating spread is 25.7 − 22.6 = 3.1 kN, or 13.7% from the lowest value (NSK) to the highest (JTEKT). The static-rating spread is only 11.6 − 11.2 = 0.4 kN, or 3.6% from the lowest (NSK) to the highest (SKF). The order therefore changes: JTEKT leads on Cr, but SKF leads on C₀. The data do not support a single overall “strongest 6305” ranking.
Why the two rankings cannot be merged: ISO 281 defines the basic dynamic radial load rating as the constant stationary radial load theoretically associated with one million revolutions of basic rating life. It is a rolling-fatigue calculation input. ISO 76 defines the basic static radial load rating using the contact stress at the most heavily loaded rolling-element/raceway contact; for ordinary radial ball bearings the reference stress is 4,200 MPa, corresponding to approximately 0.0001 times the ball diameter in total permanent deformation. C₀ is therefore a static-deformation criterion, not another expression of fatigue life or a maximum permissible operating load.
Selection path: for a predominantly rotating radial-load case, use the actual manufacturer's Cr as the input to its dynamic equivalent-load and life calculation. For stationary, slow-oscillating or shock-dominated cases, calculate the static equivalent load P₀ and static safety factor S₀ = C₀ / P₀ against the application's required margin. For combined radial and axial loads, do not assume P = Fr: ISO 281 uses Pᵣ = XFr + YFa, and the X/Y branch depends on the axial-load ratio and the bearing's f₀/C₀r inputs. The cited products publish different f₀ and C₀ values, so the same external Fa/Fr pair must be evaluated with the selected manufacturer's own calculation data.
What cannot be concluded: the higher JTEKT Cr does not prove longer field life, higher static shock tolerance or universal interchangeability. The higher SKF C₀ does not prove a higher dynamic fatigue life. The product pages do not disclose enough internal geometry, material/heat-treatment detail, or test results to explain why the published Cr values differ. SKF identifies its 6305-2Z as Explorer; that product-class label is not a conversion factor for the other manufacturers' ratings. JTEKT's cited 6305 ZZ page does not state a clearance class, so clearance equivalence is not established by this comparison.
RFQ / substitution checks: request the exact manufacturer and full designation; confirmed radial clearance and tolerance class; actual radial and axial load components and duty cycle; peak/static shock case and required S₀; speed and operating temperature; lubrication and contamination conditions; and the manufacturer's calculation basis for dynamic equivalent load and life. If the bearing must retain low noise, low vibration or precise running smoothness after a stationary shock, obtain the maker's application-specific permissible P₀ / S₀ confirmation rather than treating C₀ as an allowable load.
Scope: this is a comparison of published catalogue ratings for Koyo / JTEKT 6305 ZZ, NSK 6305ZZ and SKF 6305-2Z. All cited records state 25 × 62 × 17 mm and double-sided shield execution; the JTEKT page does not state clearance, so the comparison is not a complete like-for-like interchangeability approval. The percentage spreads are arithmetic comparisons of the published Cr and C₀ values, not measured performance differences. No load-life, static-safety or service-life value is calculated because no application loads, speed, duty cycle or required safety factor were supplied.
Sources: Koyo / JTEKT official 6305 ZZ product detail (Specification data: Cr 25.7 kN, C₀r 11.3 kN, Cu 0.860 kN, f₀ 13.2; online record checked 2026-11-25); NSK official 6305ZZ product detail (Basic Load Ratings: Cr 22,600 N, C₀r 11,200 N; Calculation factor f₀ 13.2; shield execution; online record checked 2026-11-25); SKF official 6305-2Z product detail (Performance / Calculation data: C 23.4 kN, C₀ 11.6 kN, Pu 0.49 kN, f₀ 12; online record checked 2026-11-25). ISO Rolling bearings — Dynamic load ratings and rating life, ISO 281:2007, Edition 2 (2007-02-15), Clause 3.4–3.6, printed pp. 2–3; Clause 5.1.1, printed p. 6; Clause 5.2.1 and Table 3, printed pp. 8–9: ISO 281 preview PDF. ISO Rolling bearings — Static load ratings, ISO 76:2006, Edition 3 (2006-05-01), Introduction and Clauses 3.1–3.6, printed pp. v and 1–2; ISO confirms the 2006 edition remains current after its 2020 review and lists Amendment 1:2017: ISO 76 official record; ISO 76 preview PDF.
6305 C3 — the axial-load factor depends on the clearance that remains in operation
Buyer conclusion: a C3 suffix alone does not tell you which X/Y calculation factors to use. First establish whether the bearing will retain its increased radial clearance after mounting and thermal stabilization. SKF publishes separate Normal, C3 and C4 factor columns, but explicitly says to use the Normal-clearance factors when a larger clearance was selected to offset an expected in-service reduction (for example, inner-ring heating). NSK publishes the 6305 C3 initial-contact-angle range, but its 6305 load table does not show a separate C3 X/Y factor column. Do not copy SKF's C3 coefficients into an NSK substitution.
| Manufacturer evidence | What is published | Decision boundary |
|---|---|---|
| SKF 6305-2Z/C3 | SKF's official product listing identifies 25 × 62 × 17 mm, double-sided non-contact shields and C3 radial internal clearance. | Use the SKF factor table's C3 column only when the mounted/operating bearing is being evaluated on that C3 basis; if C3 is chosen to compensate for expected clearance reduction in service, SKF directs the user to the Normal column. |
| NSK 6305 | NSK's 2025 Part C table gives Cr = 22,600 N, C₀r = 11,200 N and f₀ = 13.2. Its C3 initial contact angle for 6305 is listed as 11°–16°. | NSK's published load-factor matrix uses f₀Fa/C₀r, while its 6305 page does not provide a separate C3 X/Y matrix. Confirm the applicable factors for the exact NSK C3 execution with NSK rather than importing SKF's C3 row. |
Why this changes the calculation: in SKF's Table 2, at the exact input Fa/C₀ = 0.13, the Normal-clearance row gives e = 0.31, X = 0.56 and Y = 1.40 when Fa/Fr > e. The C3 row at the same Fa/C₀ gives e = 0.41, X = 0.46 and Y = 1.30 when Fa/Fr > e. If Fa/Fr = 0.40, the branch therefore changes: Normal clearance uses P = 0.56Fr + 1.40Fa = 1.12Fr; C3 uses Fa/Fr ≤ e and P = Fr. This is a worked comparison of SKF's published calculation branches, not a measured load test or a statement that a C3 bearing is universally more capable.
Hidden condition: SKF's catalogue note says that if a clearance greater than Normal is chosen because clearance will be reduced in operation (for example, strong inner-ring heating), the Normal-clearance factors should be used. Therefore, a buyer must specify the fit, shaft and housing materials, ring temperature difference and intended mounted operating clearance—not merely write “C3” on the RFQ. NSK's C3 contact-angle range confirms that clearance is geometrically relevant to axial loading, but does not itself provide an NSK C3 dynamic-load coefficient set.
RFQ / substitution checks: request the exact manufacturer and full suffix; unmounted clearance class and measured range; shaft/housing fits and materials; expected inner-to-outer-ring temperature difference; estimated mounted operating clearance; radial and axial load components including peak values; and the manufacturer's written X/Y/e calculation basis for the exact variant. For a high axial-load application, also ask the manufacturer to confirm shoulder support and permissible axial loading rather than relying on the dynamic equivalent-load equation alone.
Scope: the numeric branch example uses SKF's published Table 2 at Fa/C₀ = 0.13 and Fa/Fr = 0.40. It is a dimensionless worked example using the exact catalogue row, not a 6305 life calculation. The SKF 6305-2Z/C3 product listing confirms the exact C3 execution; the SKF catalogue's 6305 rating row is used only to identify the model family and is not used to infer an unlisted C3-specific rating. NSK's 6305 C3 contact-angle range is not a substitute for its load-factor confirmation. No life, allowable load or service-life guarantee is calculated.
Sources: SKF, Bearings and Mounted Products (2018), “Deep groove ball bearings — Loads,” Table 2, printed p. 38 (Normal/C3/C4 e, X and Y values and note on using Normal factors when operating clearance reduction is expected); 6305 rating row, printed p. 44: SKF catalogue PDF. SKF official product listing, 6305-2Z/C3, technical specification (dimensions, shield execution, C3 clearance), checked 2026-11-25: SKF 6305-2Z/C3 product listing. NSK, Rolling Bearings for Industrial Machinery, E1103 Part C, revised September 2025: Table 2 “Initial Contact Angle α₀, With C3 and C4 Clearances,” 6305 row, printed p. C014 (C3 = 11°–16°); 6305 rating row and dynamic equivalent-load formula/factor panel, printed p. C020 (Cr 22,600 N, C₀r 11,200 N, f₀ 13.2; factor input f₀Fa/C₀r): NSK Part C PDF; NSK official catalogue listing and revision date.
6305 C3 — initial clearance is not the mounted or operating clearance
Buyer conclusion: do not choose or approve 6305 C3 from the suffix alone. The C3 range is the unmounted starting point; shaft interference, housing interference and the temperature state of the inner ring, outer ring and rolling elements can consume part of that clearance. The three manufacturers use related but non-identical calculation models. A single generic “subtract 80% of the fit plus 5–10°C” shortcut is not a manufacturer-neutral acceptance method.
| Source model | Published method | Important assumption / limit |
|---|---|---|
| SKF | Δrfit = Δ1f1 + Δ2f2; for steel shaft and steel/cast-iron housing, Δrtemp = 0.012 ΔT dm, with dm = (d + D)/2. | Fit factors f1/f2 depend on d/D and the stated solid-shaft, thick-wall housing construction. SKF says use maximum probable effective interference for the fit calculation. |
| NSK | δeff = δ0 − (δf + δt); δf = (0.70–0.90)Δdeff; δt = αΔTiDo, with α = 12.5 × 10⁻⁶/°C and, for ball bearings, Do = 0.20(d + 4D). | The 70–90% range is a broad estimate; NSK says fit reduction depends on ring, shaft and housing geometry and materials. The thermal term uses the outer-ring raceway diameter approximation. |
| JTEKT / Koyo | S = So − (Sf + St1 + St2) + Sw. It separates inner-ring/outer-ring temperature difference from rolling-element/outer-ring temperature difference. | The published model assumes a steel shaft and housing for Table 10-1; JTEKT says Sw is generally small and may be ignored, and advises consultation for non-steel parts or special conditions. |
6305 thermal-only comparison (calculated, not measured): the cited SKF and NSK formulas can be evaluated with the same 6305 envelope, d = 25 mm and D = 62 mm. SKF uses dm = (25 + 62)/2 = 43.5 mm, so at an assumed inner/outer-ring temperature difference of 10°C its estimated thermal clearance reduction is 0.012 × 10 × 43.5 = 5.22 μm. NSK uses Do = 0.20(25 + 4 × 62) = 54.6 mm, so its estimate is 12.5 × 10⁻⁶ × 10 × 54.6 mm = 0.006825 mm = 6.825 μm. The arithmetic difference is 1.605 μm (about 31% of the SKF estimate). This is not proof that one manufacturer is wrong: the formulas use different characteristic diameters and are approximate models. It is a warning not to combine one manufacturer's thermal term with another manufacturer's fit factors or clearance limits.
JTEKT's method adds a further distinction: its temperature term is split into t1 (inner ring minus outer ring) and t2 (rolling element minus outer ring). The page therefore cannot calculate the JTEKT thermal reduction from a single ring-to-ring temperature difference unless the rolling-element temperature assumption is also supplied. A nominal “10°C ring difference” is not a complete thermal input to that model.
What this means for C3 selection and substitution: the existing SKF 6305 initial C3 band of 13–28 μm is not an installed-clearance promise. Under the 10°C illustration above, the thermal term alone consumes about 5.2 μm (SKF model) or 6.8 μm (NSK model), before any fit reduction is deducted. The remaining clearance cannot be determined without the actual effective shaft and housing interference, their materials and geometry, and the operating temperature state. A replacement brand with the same “C3” marking is therefore not approved merely because its initial clearance group matches: compare the actual guaranteed initial range, fit calculation basis, thermal model and required operating-clearance window.
RFQ and receiving checks: state the exact manufacturer and full suffix; request the guaranteed unmounted C3 range and the measurement-load correction/method; provide shaft diameter tolerance and material, housing bore tolerance and material, solid or hollow shaft, housing wall construction, expected radial load and rotating ring, steady-state and start-up inner-ring/outer-ring temperatures, and any known rolling-element temperature estimate. Ask the supplier/manufacturer to return the calculated residual clearance after mounting and minimum operating clearance, identifying the formula and assumptions. At receiving inspection, compare a measured value only after applying the matching manufacturer's measurement-load correction; do not compare raw gauge readings directly with theoretical clearance limits.
Scope: the 5.22 μm and 6.825 μm figures are formula outputs for an assumed 10°C ring temperature difference using the common 6305 dimensions, not measured temperatures, residual-clearance values or application guarantees. They exclude fit reduction, load effects, misalignment, axial clamping, housing deformation, non-steel expansion and transient thermal peaks. Do not use these simplified terms for non-steel shafts/housings, thin-wall or unusual structures, or to release a production fit without manufacturer application review. A zero or negative calculated operating clearance is not automatically an approved preload.
Sources: SKF, Rolling bearings, PUB BU/P1 17000/1 EN, October 2018, B.7 “Selecting internal clearance or preload”, printed pages 184–185 (Δrfit equation, Diagram 2 fit factors, Δrtemp equation, steady-state/start-up distinction and minimum initial-clearance relation); NSK, Rolling Bearings, CAT. No. E1154f, 2013, Section 5.2 “Internal clearance selection”, equations (5.1)–(5.4), printed pages E-8–E-9 (70–90% fit reduction, α and ball-bearing Do approximation); JTEKT / Koyo, Basic Bearing Knowledge, Section 10 “Operating clearance”, Table 10-1, accessed 2026-11-25 (steel-shaft/housing model, S = So − (Sf + St1 + St2) + Sw, separate ring and rolling-element temperature terms, special-material caution). Model dimensions: SKF official 6305/C3 product detail and NSK official 6305C3 product detail, both 25 × 62 × 17 mm.
Applications and selection notes
Deep groove ball bearings are the default radial bearing for electric motors, fans, pumps, gearboxes, agricultural machinery and general industrial equipment. The single-row design carries radial load and a limited axial load in both directions, needs no adjustment after mounting, and runs at higher speeds than most alternative types of the same size.
In the sealed (2RS) and shielded (ZZ) executions, the bearing is lubricated for life and maintenance-free under normal operating conditions, which is why motor and appliance manufacturers standardise on them. In the open execution, the bearing is lubricated from the housing or shaft — the usual choice when the surrounding assembly provides filtration, re-lubrication or oil-bath lubrication.
How to read the specification table
Read the specification table against three limits. Boundary dimensions (bore, outside diameter, width) decide whether the bearing fits the shaft and housing — these are standardised designation-bound values and interchangeable across conforming manufacturers. Load ratings (Cr, C0r) describe different failure checks: Cr is used for rolling-fatigue life under dynamic load; C0r is the ISO 76 basic static rating tied to a defined contact-stress / permanent-deformation criterion, not a universal allowable working load.
Do not approve a bearing from C0r alone. For a deep-groove ball bearing, first convert the actual radial/axial load combination to the equivalent static load P0 using the exact maker’s X0/Y0 factors, then calculate s0 = C0r / P0. The required s0 is an application criterion, not a suffix or a universal constant: NTN’s Precision Rolling Bearings catalogue (Table 3.3) gives minimum values for ball bearings of 2 for quiet-rotation applications, 1.5 for impact-load applications and 1 for normal-rotation applications, and explicitly says vibration/shock requires a shock-load factor in P0 max. SKF’s 2018 general catalogue separately classifies rotating versus non-rotating duty, quiet-running requirement and shock severity in Table 5, and says to use the maximum load that can occur. These tables are not a common test or a directly transferable brand ranking; their application categories differ. For ordinary aligned arrangements, use the exact maker’s C0r, X0/Y0 and stated duty assumptions. Where shaft/housing tilt, misalignment, moment load or operating clearance materially changes rolling-element load sharing, the simplified ISO 76 C0/P0 check may miss the peak-loaded element: ask for an effective static safety-factor calculation using ISO 17956:2025 or an equivalent documented internal-load-distribution method. ISO 17956 adds tilt/misalignment, operating clearance and internal load distribution; it checks static deformation only, not fatigue life, false brinelling, wear or microspalling. In the RFQ, provide peak radial and axial loads, shock duration/direction, rotation state, required quietness, operating clearance, shaft/housing misalignment and moment load; request the maker’s P0 factors, selected s0 basis and calculation assumptions. Do not use Cr as a substitute for this static check or treat a passing basic C0/P0 ratio as proof for a tilted or moment-loaded assembly.
Limiting speeds are catalog values established for the manufacturer’s execution, clearance and lubrication; they are not an operating recommendation for your application. Sealed and shielded executions, heavy fits, elevated temperature or misalignment all reduce the usable speed. Confirm the speed and clearance choice against your actual conditions before ordering — the internal-clearance class in particular should follow fit, temperature and speed, not a default.
Cross reference: see how 6305 relates to its ZZ / 2RS executions and the rest of its series — boundary dimensions first, execution and clearance confirmed per application on the bearing cross reference page.
Related engineering knowledge
Background reading that supports the selection decision on this page — failure modes, seal trade-offs and lubrication behavior. These articles explain the engineering; the specifications and supply commitments live on this page and in the quotation.
6305 — buying questions
What does the designation 6305 mean?
6305 is a standard boundary-dimension designation: the dimension series fixes the outside diameter and width proportions, and the bore code fixes the bore diameter — 25 mm for this bearing. Two bearings carrying the same designation from conforming manufacturers are dimensionally interchangeable; execution (seals, clearance class, cage) is the part that can differ, so state the execution you need when you request a quotation.
Are the catalog load rating and speed of 6305 enough for my application?
The table lists Basic dynamic load rating (Cr) = 25.7 kN and grease-lubricated limit 11000 min-1 and oil-lubricated limit 13000 min-1. The load rating is the starting point of a life calculation, and each speed is a catalog limit for the manufacturer’s execution, not an application operating recommendation. Seals, fits, temperature and lubrication all affect the usable speed in a real assembly. Both lubricant-specific limits are listed; compare each only under its stated lubricant and manufacturer execution. Send the application conditions with your inquiry and we confirm suitability before quoting; do not size from the catalog speed alone.
What information do you need to quote 6305?
Four things, in one message: the designation (and execution — seals, clearance class, precision class, if not standard), the quantity, the destination country, and any documents you require. Application conditions such as speed, load direction and temperature are welcome and let us verify the execution instead of assuming it. Quotation, lead time and the exact document set come back in writing.
Ordering & documentation
Documents
The documents available for 6305 depend on the actual supplying source and order. State any required export, origin, material or inspection documents in your inquiry; the available document set is confirmed in writing with the quotation.
Quotation
To quote 6305, send: the designation and required execution, quantity, destination country, and any required documents. Adding the application conditions (speed, load direction, temperature, fit) lets us confirm the execution and clearance class instead of quoting blind.
Sample & supply
If you need an evaluation sample of 6305, state the required quantity and timing. Sample feasibility, source, price and dispatch timing are confirmed in the quotation; sample availability is not assumed from the standard designation alone.
Lead time for this designation and quantity is confirmed in the quotation against the actual supplying source and availability. Any applicable certificates and quality documents are confirmed for the actual supplying source and product; available documents are stated in the quotation.
Storage & shipping
Store bearings flat in their original, unopened packaging in a dry indoor area away from temperature swings. Confirm the actual preservation method, packaging, marking and transport protection for the supplying source and order before shipment. Do not rotate a bearing through its rolling elements during handling or mounting.