Specifications

SpecificationValueParameter classSource publisher
Bore diameter (d) 25 mm Model designation & boundary dimension jtekt.co.jpManufacturer-published specification
Outside diameter (D) 52 mm Model designation & boundary dimension jtekt.co.jpManufacturer-published specification
Width (B) 15 mm Model designation & boundary dimension jtekt.co.jpManufacturer-published specification
Basic dynamic load rating (Cr) 17.5 kN
Basic dynamic load rating is a catalog reference used in bearing-life calculations; confirm equivalent load, speed, reliability and required service life for the application.
Manufacturer catalog reference — not a supply guarantee jtekt.co.jpManufacturer-published specification
Basic static load rating (C0r) 7.85 kN
Basic static load rating is a catalog reference; verify equivalent static load and the required static safety factor for the application.
Manufacturer catalog reference — not a supply guarantee jtekt.co.jpManufacturer-published specification
Limiting speed, grease lubrication 13000 min-1
Catalog limiting speed for grease lubrication, not an application operating recommendation. Confirm lubricant, temperature, load, sealing and duty conditions before selection.
Manufacturer catalog reference — not a supply guarantee jtekt.co.jpManufacturer-published specification
Limiting speed, oil lubrication 15000 min-1
Catalog limiting speed for oil lubrication, not an application operating recommendation. Confirm lubricant, temperature, load, sealing and duty conditions before selection.
Manufacturer catalog reference — not a supply guarantee jtekt.co.jpManufacturer-published specification
Shaft abutment diameter (da min.) 30 mm Model designation & boundary dimension jtekt.co.jpManufacturer-published specification
Housing abutment diameter (Da max.) 47 mm Model designation & boundary dimension jtekt.co.jpManufacturer-published specification
Reference mass 0.128 kg Manufacturer catalog reference — not a supply guarantee jtekt.co.jpManufacturer-published specification
Fillet radius (r max.) 1 mm Model designation & boundary dimension bearingcalculators.comIndustry reference chart

Parameter classes: Model designation & boundary dimension — what identifies the model (boundary dimensions follow the designation). Manufacturer catalog reference — the named manufacturer's published catalog data for this designation; it is not a guarantee that every unit we supply reaches these exact figures. Industry reference — a third-party or industry-published value; it is not specific to the named manufacturer and is not a supply guarantee. Supplier-confirmed — a value we have confirmed for our own supply. Order-confirmed — the value fixed in a specific order. None of the values on this page are supplier-confirmed yet; supply-specific figures (tolerance class, clearance, seal variant availability, lead time) are confirmed with your quotation.

The source publisher shown on each row identifies where that parameter was published; it is not necessarily the manufacturer supplying your order. Manufacturer-published specifications are linked where the source is approved for public linking. Industry-reference publishers are shown as text.

All values above are model-bound catalog values traceable to a collected source. Fields without collected evidence are not published; ask with your inquiry and we confirm them at quotation.

Manufacturer / model attribution: Koyo / JTEKT — 6205 (open). This is the manufacturer named by the model-evidence record; it does not establish that every item supplied for an inquiry comes from this manufacturer. The actual manufacturer, original model and supplying source are confirmed in the quotation.

Specifications sourced from jtekt.co.jp (manufacturer-published specification); bearingcalculators.com (industry reference chart).
Source per specification field
SpecificationSource
Bore diameter (d) jtekt.co.jp — manufacturer-published specification
Outside diameter (D) jtekt.co.jp — manufacturer-published specification
Width (B) jtekt.co.jp — manufacturer-published specification
Basic dynamic load rating (Cr) jtekt.co.jp — manufacturer-published specification
Basic static load rating (C0r) jtekt.co.jp — manufacturer-published specification
Limiting speed, grease lubrication jtekt.co.jp — manufacturer-published specification
Limiting speed, oil lubrication jtekt.co.jp — manufacturer-published specification
Shaft abutment diameter (da min.) jtekt.co.jp — manufacturer-published specification
Housing abutment diameter (Da max.) jtekt.co.jp — manufacturer-published specification
Reference mass jtekt.co.jp — manufacturer-published specification
Fillet radius (r max.) bearingcalculators.com — industry reference chart
6205 deep groove ball bearing, open type with exposed balls and cage, face-on product photograph on a plain light backdrop (illustrative)
Product illustration (AI-generated, illustrative only) — bearings are standardized parts; the supplied product is confirmed at quotation.

6205 grease fill — the percentage denominator changes the instruction

Buyer conclusion: never approve a grease-fill percentage until the supplier states what space the percentage refers to. “30% fill” may mean 30% of the bearing's internal free volume or 30% of the housing space left after the shaft and bearing are installed. Those are different volumes and different lubrication instructions. A factory-greased, double-sided sealed 6205 is a third case: do not apply an open-bearing / housing fill rule to it or add grease at mounting unless the exact manufacturer procedure explicitly requires it.

Manufacturer / source Published instruction Denominator and condition What it does not authorize
SKF For a bearing mounted in a housing, fill the bearing to 100% and the housing free space to 30–50%. For very-low-speed, non-vibrating service where contamination protection is important, housing free space may be filled up to 90%. If running-in cannot be performed, reduce the initial fill to no more than 30% of the bearing free volume. SKF explicitly distinguishes the bearing cavity from the housing free space. The 30% bearing-volume limit is conditional on omitting running-in; it is not the ordinary housing-fill recommendation. Do not read “30%” as a universal fill for the whole bearing arrangement. SKF also states that double-sided shielded/sealed bearings are factory-greased and need no additional grease at mounting.
NSK First apply sufficient grease to the bearing interior and specified guide surfaces. Then fill the housing's free internal space to 1/2–2/3 when speed is at or below 50% of limiting speed, or 1/3–1/2 when above 50%. The percentage is explicitly the housing free space excluding the shaft and bearing. The speed trigger is relative to that bearing's grease-lubricated limiting speed, not a universal RPM threshold. NSK's published bands overlap exactly at 50% (one says at or below, the other at or above); the source does not resolve which housing-fill band governs at that exact point, so request manufacturer clarification rather than choosing one. Do not apply these housing percentages to the sealed bearing's internal grease charge or to a different housing geometry without recalculating its free volume.
FAG / Schaeffler Pack bearing cavities to capacity as a general rule; only partly fill 20–35% of free space for extremely fast-running bearings. For the two lateral housing cavities, the table gives full fill below n·dₘ = 50,000 min⁻¹·mm and 60% from 50,000 to 500,000 min⁻¹·mm. Sealed or shielded bearings are packed with grease to approximately 35% during manufacture. The source gives separate rules for bearing cavities, lateral housing cavities and factory-filled sealed/shielded bearings. dₘ = (D + d)/2; the housing-space rule is indexed by n·dₘ. The 35% manufacturing fill is not an instruction to add 35% grease during installation, and the 20–35% high-speed bearing-space rule is not the same as the housing-cavity percentage.
Koyo / JTEKT Its general guidance says approximately one-third to one-half of the “inside space”; at low speed, two-thirds to full is sometimes used. It warns that excessive grease churns, generates heat and can deteriorate or soften. The page says the amount varies with bearing structure and housing internal space, but does not define a denominator as precisely as the NSK and SKF instructions. Do not convert this broad guidance into a universal 6205 factory-fill quantity or claim it is numerically equivalent to another maker's housing-space percentage.

The cross-source finding is about the denominator, not a contest over the “right” percentage. SKF's ordinary mounted-bearing guidance separates a fully filled bearing from a partly filled housing. NSK likewise says to grease the bearing interior first, then calculates a separate percentage for the housing's free volume. FAG separates bearing cavities from the two lateral housing cavities and adds a distinct manufacturing fill for sealed/shielded bearings. JTEKT's broad “inside space” wording is less explicit about the denominator. These instructions therefore cannot be collapsed into a single cross-brand 30%, 35% or 50% rule.

Why this changes a 6205 purchase or installation decision: the cited FAG 6205-C-2HRS>V record identifies GA14 factory grease but does not state its fill mass, volume or percentage. That missing quantity must remain “not published in this record”; it cannot be filled in using FAG's generic approximately 35% manufacturing statement as a verified value for that exact SKU. SKF's maintenance handbook separately says double-sided shielded/sealed bearings are greased at the factory and require no additional grease at mounting. The buyer should therefore distinguish (1) a sealed, factory-greased 6205, (2) an open 6205 greased before or during installation, and (3) the housing's reserve / purge space. A housing fill percentage is not the sealed bearing's factory grease charge.

Running-in is part of the quantity decision: SKF recommends increasing speed progressively from a low starting speed so excess grease can distribute or escape and operating temperature can stabilize. If this cannot be done, SKF's stated alternative is a maximum 30% of the bearing's free volume. This is not a contradiction with SKF's 100% bearing-fill general rule; the operating procedure has changed. NSK separately gives sealed deep-groove grease-life equations only within stated conditions: 0.25 ≤ n/Nmax ≤ 1, P/C ≤ 0.1, and temperature bands of 70–110 °C for general-purpose grease or 70–130 °C for wide-temperature grease (with its stated below-70 °C convention). NSK defines Nmax here as the grease-lubricated limiting speed and notes catalog values with non-contact seals. The 50% overlap in its housing-fill guidance should also be clarified for the exact bearing execution. Those conditions are a model boundary, not a universal guarantee of sealed-bearing life.

RFQ and receiving checks: identify whether the ordered 6205 is open, shielded or contact-sealed; request the exact manufacturer's grease code, base-oil / thickener information where available, factory fill mass or volume (or an explicit statement that it is not disclosed), and whether the unit is factory lubricated for life. For an open bearing in a housing, provide bearing dimensions, shaft and housing geometry, calculated housing free volume, speed and duty cycle; ask the supplier to state separately the grease quantity inside the bearing and in each housing cavity, the percentage denominator, and the running-in / purge arrangement. For a sealed bearing, do not regrease by analogy with open-bearing instructions; confirm any exception with the originating manufacturer.

Scope and limits: this is a comparison of general manufacturer maintenance guidance, not a validated grease-mass calculation for a particular 6205 housing. The cited sources cover different bearing arrangements, speed bands and maintenance situations; their percentages are not controlled head-to-head test results. No grease mass is calculated because the exact free volumes, housing geometry, grease density and product-specific factory fill are not available. The FAG GA14 code for 6205-C-2HRS>V does not disclose a quantity in the cited selected-product record. Do not use this section to open a sealed bearing, change its factory grease, set a relubrication interval, or approve a specific high-speed application without the exact product and application data.

Sources: SKF, Bearing Maintenance Handbook, PUB SR/P7 10001/1 EN, September 2011, Chapter 7 “Lubrication”, “How to grease bearings and associated components on initial installation” and “The right quantity”, printed pp. 189–190 (factory grease on double-sided closed bearings; 100% bearing fill / 30–50% housing free space / 90% low-speed exception / 30% bearing-free-volume limit when running-in cannot be done); same chapter, “Running-in of grease lubricated bearings”, printed p. 191 (progressive speed and temperature stabilization); NSK, Bearing ABCs, Section 9.1 “Grease Lubrication”, online page accessed 2026-11-25, “Grease Fill (Grease Quantity)” and “Grease Life of Sealed Deep Groove Ball Bearings” (housing free-space percentages, temperature, n/Nmax and P/C applicability); FAG / Schaeffler, Mounting and Dismounting of Rolling Bearings, Publ. No. WL 80 100/3 EA, status 2004, Section 5 “Lubrication”, printed p. 69 (bearing-cavity fill, 20–35% very-high-speed rule, n·dₘ housing-cavity table and approximately 35% factory fill for sealed/shielded bearings); Koyo / JTEKT, Basic Bearing Knowledge, Section 12-1-1 “Grease lubrication”, “Amount of grease”, online page accessed 2026-11-25 (one-third to one-half general guidance, two-thirds to full at low speed, and churning/heat warning); Schaeffler official selected-product record for FAG 6205-C-2HRS>V, generated 2026-05-21 (GA14 grease identity; no fill quantity stated). SKF handbook; NSK grease-lubrication guidance; FAG mounting handbook; JTEKT lubrication guidance; FAG 6205-C-2HRS>V selected-product record.

)}

FAG 6205-C-2HRS>V — seal, grease, clearance and temperature execution

Schaeffler's selected-product technical sheet identifies this as the exact FAG 6205-C-2HRS>V variant, not a generic 6205 specification. It is a Generation C, single-row deep-groove ball bearing with contact seals on both sides. The manufacturer lists the following variant-specific configuration and limits.

Variant attribute FAG 6205-C-2HRS>V Buyer interpretation
Boundary dimensions (d × D × B)25 × 52 × 15 mmConfirm the 25 mm shaft, 52 mm housing bore and 15 mm axial envelope
Seal execution2HRS — contact seals on both sidesBoth sides have contact seals; do not confuse with non-contact 2Z shields
CageJN — steel sheet-metal cageVariant-specific cage material and construction
Tolerance classP6 (Class 6)Manufacturer's stated tolerance class; not a supplier measurement report
Radial internal clearanceCN (Group N)Normal clearance class; not a measured single-bearing clearance value
Factory greaseGA14 — low-noise ball-bearing greaseGrease identity is specified; thickener chemistry, base-oil viscosity and fill quantity are not stated on this sheet
Operating temperature−20 to +100 °CUse this as the stated operating range for this selected variant
Ring dimensional stabilizationSN — up to 120 °CSeparate ring-stability attribute; it does not extend the stated +100 °C operating limit
Basic dynamic radial load rating (Cr)15.9 kNCatalogue rating for life calculation, not an application-specific allowable load
Basic static radial load rating (C0r)7.8 kNCatalogue rating for static safety assessment, not a permissible load by itself
Fatigue load limit (Cur)0.53 kNManufacturer fatigue-load reference
Limiting speed (nG)12,200 min⁻¹Catalogue limiting speed; actual suitability depends on load, heat, lubricant and installation
Shaft shoulder diameter da(min.)30.6 mmMinimum shaft abutment diameter
Housing shoulder diameter Da(max.)46.4 mmMaximum housing abutment diameter
Maximum fillet radius ra(max.)1 mmMating corner radius must clear the bearing chamfer

Temperature boundary: the technical sheet lists operating temperature from −20 to +100 °C and separately lists SN ring dimensional stabilization up to 120 °C. These are different attributes: the stabilization figure is not permission to operate the complete sealed, grease-filled bearing continuously at 120 °C.

Identification boundary: Schaeffler states that version code >V is not marked on the bearing itself. Confirm the full 6205-C-2HRS>V designation from the order confirmation or product documentation; do not claim that visual inspection of the bearing alone can verify the >V code. These values belong to this selected FAG variant and must not be transferred to generic 6205, another clearance suffix, or another manufacturer's bearing.

Scope: FAG / Schaeffler 6205-C-2HRS>V selected-product record only. The stated GA14 grease does not disclose thickener chemistry, base-oil viscosity, fill quantity or relubrication procedure. The catalogue load and speed values are not application guarantees; verify actual load spectrum, temperature, fit, duty cycle and the ordered variant before selection.

Source: Schaeffler official selected-product technical sheet for FAG 6205-C-2HRS>V (variant configuration and technical data: seal, cage, P6, SN, GA14, CN, dimensions, load ratings, limiting speed, operating temperature and mounting dimensions).

SKF 6205-2Z/VA208 — high-temperature execution, load and mounting limits

SKF lists 6205-2Z/VA208 as a high-temperature deep-groove ball bearing. This is not the standard grease-filled 6205-2Z: the VA208 execution uses a segmented graphite cage, graphite-based solid lubrication, manganese-phosphate-treated rings and rolling elements, and non-contact shields on both sides.

Buyer check SKF 6205-2Z/VA208 Selection meaning
Boundary dimensions (d × D × B)25 × 52 × 15 mmSame ISO envelope as a standard 6205; this does not make the internal execution interchangeable
Cage and lubricationSegmented graphite cage; graphite-based solid lubricationDesigned for high-temperature, low-speed operation; do not add conventional grease or oil
Closure2Z — non-contact shields on both sidesHelps exclude solid contaminants; not a liquid-tight contact seal
Lubricant classificationNSF H1 listed for VA208Lubricant classification only; not a certification that the complete bearing is approved for direct food contact
RelubricationLubricated for life; no relubricationNo routine grease/oil replenishment procedure applies to this execution
Maximum operating temperature350 °CManufacturer's maximum for VA208, not an approval for every load/speed combination
Limiting speed110 r/minVery low-speed design; do not use standard 6205 speed figures
Basic static load rating (C₀)7.8 kNUse with SKF's high-temperature static-load sizing method, not as a direct allowable load
Radial internal clearance136–192 μmSKF Table 4, 24–30 mm bore band; unmounted bearing under zero measuring load
Shaft abutment diameter (da)30.6–34.3 mmManufacturer's abutment range for the shaft shoulder
Housing abutment diameter (Da max.)46.4 mmMaximum housing shoulder diameter
Maximum fillet radius (ra max.)1 mmKeep the mating corner within the manufacturer's limit

Static-load screen at 350 °C

SKF Table 5 requires a basic static load rating C₀req of 9 kN for an equivalent static load P₀ = 2 kN at temperatures up to 350 °C. This model's C₀ is 7.8 kN, so it does not meet that particular catalogue sizing case. The table applies only when P₀ = Fr, Fa < 0.8 Fr and Fa < 0.15 C₀; it is not a universal pass/fail rule for other load combinations.

Fit, alignment and mounting conditions

  • For a solid steel shaft with a rotating inner-ring load, SKF Table 6 specifies shaft tolerance k6 and housing tolerance F7.
  • For a stationary inner-ring load, the corresponding table values are shaft g6 and housing J7. These are conditional fit recommendations, not dimensions of the bearing itself.
  • SKF gives approximately 20–30 arcmin permissible misalignment only when the bearing rotates slowly; misalignment increases noise and reduces service life.
  • Use hot mounting; an induction heater is preferred. Do not mount by impact and do not heat the bearing by immersion in hot oil.
  • SKF notes that high-temperature bearings have limited corrosion protection and should be used in a dry environment or with a suitable external sealing solution to keep them dry.

Selection boundary: 350 °C is the VA208 maximum temperature, while 110 r/min is its limiting speed. Both constraints matter. The 136–192 μm clearance is an unmounted catalogue range, not installed or operating clearance. Confirm the actual temperature at the bearing, radial/axial load, speed, fit, contamination, corrosion exposure and ordered suffix before selecting it. Do not transfer these figures to standard 6205, 6205-2Z/VA201, 6205-2Z/VA228 or another manufacturer's product.

Sources: SKF official 6205-2Z/VA208 product information; SKF Rolling bearings, PUB BU/P1 17000/1 EN (October 2018), Chapter 18: Table 1 and variant description, printed page 1009; Table 4 (radial clearance) and Table 5 (static-load sizing), printed page 1012; design considerations, printed page 1013; relubrication and mounting, printed page 1014; exact 6205-2Z/VA208 row, printed page 1016. Open SKF catalogue PDF.

6205-2Z/VA208 — 350 °C is not a complete thermal or interchangeability rating

Buyer decision: do not approve a VA208 replacement from the “350 °C” label alone. SKF's current product page and its April 2024 high-temperature catalogue publish different limiting speeds for the same 6205-2Z/VA208 designation (110 versus 120 r/min). The same catalogue also states that the deep-groove high-temperature bearing range has a dimensional-stability temperature of 120 °C, and that some dimensional change is expected above the standard heat-stabilization condition even though VA208's maximum operating temperature is 350 °C. Keep these as separate constraints; neither number should be silently substituted for the other.

Evidence itemPublished statementBuyer interpretation
SKF current 6205-2Z/VA208 product page25 × 52 × 15 mm; C₀ = 7.8 kN; limiting speed 110 r/min; maximum operating temperature 350 °C; clearance “multiples of C5”; high-temperature steel, solid lubricant, coated, non-contact shieldsExact SKU-level product data; speed and temperature still require application confirmation
SKF high-temperature catalogue, PUB BU/P2 14961/4 JA, April 2024, printed p.20Same 6205-2Z/VA208 row: 25 × 52 × 15 mm; C₀ = 7.8 kN; limiting speed 120 r/min; maximum temperature 350 °CConflicts with the current product page's 110 r/min; the public sources do not explain the revision or governing value
SKF high-temperature catalogue, printed p.18, “Bearing data” and Table 7Deep-groove high-temperature bearing dimensional-stability temperature: 120 °C; the catalogue says rings, rolling elements and cage have the same heat-stabilization treatment as standard bearings and some dimensional change is expected at very high temperature. For d = 25 mm, Table 7 gives 136–192 μm, a multiple of C5, before mounting and at zero measuring load350 °C is the product's maximum operating-temperature rating, not a statement that dimensional stability is guaranteed to 350 °C; the clearance range is unmounted initial clearance, not installed or operating clearance
NTN dimensional-stabilization guidanceTS2: 160 °C / a₂ = 1.00; TS3: 200 °C / a₂ = 0.73; TS4: 250 °C / a₂ = 0.48A different manufacturer's treatment framework; not a VA208 cross-reference or an interchangeable suffix

Why “temperature” is not one variable: SKF's VA208 approach is a purpose-designed high-temperature bearing execution: high-temperature steel, graphite-based solid lubrication, segmented graphite cage, manganese-phosphate surface treatment, non-contact shields and unusually large initial radial clearance. The catalogue describes 350 °C as the maximum operating temperature for VA208, but separately gives 120 °C as the dimensional-stability temperature for its deep-groove high-temperature bearing range. Therefore the 350 °C figure must not be rewritten as “no dimensional change up to 350 °C.”

NTN describes a different route for high-carbon chromium bearing steel: conventional heat-treated material may change dimensions during prolonged high-temperature use; TS treatment improves dimensional stability but reduces overall hardness. NTN therefore adjusts rating life using Lna = a1 × a2 × a3 × L10. Its Table 3.3 gives a₂ = 1.00 / 0.73 / 0.48 for TS2 / TS3 / TS4 respectively. If all other life inputs were held equal, a₂ = 0.48 scales the adjusted-life result to 48% of the unadjusted a₂ = 1 case; this is a formula consequence, not a measured life result for any particular bearing. NTN's table is general treatment guidance and does not prove that a specific NTN 6205 order carries TS4 or is suitable for a 350 °C application.

Substitution boundary: SKF VA208 and NTN TS2/TS3/TS4 are not equivalent temperature grades. VA208's solid-lubricant system, cage, clearance, coating and 350 °C operating-temperature claim cannot be inferred from an NTN TS suffix. Conversely, an NTN TS treatment and its a₂ factor do not establish that the bearing has a solid lubricant, high-temperature cage, 2Z shields, or the same low-speed operating envelope as VA208. Do not substitute a standard 6205 with a larger C3/C5 clearance or a TS suffix on temperature alone.

RFQ / incoming acceptance: request the exact original manufacturer and full designation; written maximum continuous and intermittent bearing temperature; the temperature at the bearing rings rather than only furnace/ambient temperature; permitted speed and the governing catalogue revision; load spectrum and the maker's high-temperature static-load check; initial clearance measurement and measurement load; shaft/housing fit and hot-state residual clearance; lubricant type and whether relubrication is prohibited; dry/wet atmosphere and external sealing; and the ordered batch's marking and inspection evidence. For SKF 6205-2Z/VA208 specifically, ask SKF to reconcile 110 versus 120 r/min in writing before fixing the purchase specification.

Scope and limits: this comparison concerns SKF's exact 6205-2Z/VA208 execution and NTN's general TS dimensional-stabilization method. The SKF 110/120 r/min difference is a same-manufacturer publication conflict, not an independent cross-brand performance difference; no basis was found to select either value as universally controlling. NTN's TS2/TS3/TS4 factors are general catalogue guidance, not model-specific data for an identified NTN 6205. No common-temperature, common-load endurance test or application calculation was found. The page does not approve a replacement or guarantee service life.

Sources: SKF, 6205-2Z/VA208 — Deep groove ball bearings, official current product page (25 × 52 × 15 mm; C₀ 7.8 kN; 110 r/min; 350 °C; high-temperature steel; solid lubricant; multiples of C5), accessed 2026-11-25: SKF product record. SKF, SKF High Temperature Bearings, PUB BU/P2 14961/4 JA, April 2024, printed p.18 (“Bearing data”, dimensional-stability temperature and Table 7, 24–30 mm clearance band), printed p.20 (6205-2Z/VA208 row: 120 r/min, C₀ 7.8 kN, 350 °C): SKF high-temperature catalogue PDF. NTN, Ball and Roller Bearings, CAT. No. 2203-3/E, 2024 edition, §3.3.2, Table 3.3, printed p. A-22 (TS2/TS3/TS4 temperature and a₂ factors; explanation of hardness reduction and adjusted rating life): NTN catalogue PDF.

SKF 6205-2Z/C3GJN vs 6205-2RSH/C3GJN — shield or low-friction contact seal?

SKF publishes both exact C3GJN executions in the same 6205 size. They share the 25 × 52 × 15 mm envelope, C3 radial-clearance class, 14.8 kN basic dynamic rating, 7.8 kN basic static rating and 28,000 r/min reference speed. The main buyer decision is the closure: non-contact metal shields for the higher limiting speed, or low-friction contact seals for a stronger integral barrier against lubricant loss and contaminants.

Buyer check SKF 6205-2Z/C3GJN SKF 6205-2RSH/C3GJN
Boundary dimensions (d × D × B)25 × 52 × 15 mm25 × 52 × 15 mm
Basic dynamic load rating C14.8 kN14.8 kN
Basic static load rating C₀7.8 kN7.8 kN
Radial internal clearanceC3C3
Reference speed28,000 r/min28,000 r/min
Limiting speed14,000 r/min8,500 r/min
Closure on both sidesMetal shield; non-contactLow-friction contact seal
CageSheet metalSheet metal
Lubricant designationGJN greaseGJN grease
Relubrication featureWithoutWithout
SKF performance classSKF ExplorerSKF Explorer

Selection boundary: consider 6205-2Z/C3GJN when lower closure friction and the higher 14,000 r/min catalogue limiting speed matter, and the application can tolerate a non-contact shield rather than a contact seal. Consider 6205-2RSH/C3GJN when the application benefits from a contact barrier on both sides and can operate within its lower 8,500 r/min limiting speed. Neither item page specifies a universal water-ingress rating; do not describe either execution as waterproof.

The equal 28,000 r/min reference speeds do not erase the difference in limiting speed. SKF distinguishes reference speed as a thermal reference from limiting speed as a mechanical limit; the actual permissible operating speed still depends on load, lubrication, heat dissipation, mounting and the surrounding application.

Both designations carry the same C3GJN suffix combination. SKF identifies C3 as radial internal clearance greater than Normal, and GJN as a urea-based high-temperature grease with a wide operating-temperature range and quiet-running characteristics. The item pages list grease lubrication and no relubrication feature. GJN describes the grease selection; it is not by itself a temperature rating for the complete sealed bearing, because the seal material and operating conditions also constrain the assembly.

Scope: this comparison is limited to the two exact SKF product designations 6205-2Z/C3GJN and 6205-2RSH/C3GJN. It does not transfer to plain 6205, 6205-2Z/VA208, 6205-2RSH without the same suffix, another manufacturer's 6205, or an unverified supply batch. The catalogue C3 class is not an individual bearing's measured clearance.

Sources: SKF 6205-2Z/C3GJN product page; SKF 6205-2RSH/C3GJN product page; SKF deep-groove bearing designation system (C3 and GJN suffix meanings); SKF Bearings and Mounted Products, printed p. 5 (GJN grease description).

6205 seal suffixes — a contact-seal label is not a seal-design interchange code

Buyer conclusion: treat 2RS, DDU, 2HRS and 2RSH as manufacturer-specific designations, not as proof of identical seal lips, friction, water exclusion or grease retention. The useful first comparison is the seal's functional construction class: shield, non-contact seal, extremely light-contact / low-torque seal, or contact seal. Even within one class, the seal geometry, elastomer and performance limits remain manufacturer-specific.

ManufacturerPublished designation / definitionWhat the buyer must not infer
Koyo / JTEKTZZ = shield; 2RU = non-contact seal; 2RS / 2RK = contact seal; 2RD = extremely light-contact seal.2RD is a distinct category, not simply another spelling of 2RS. The catalogue taxonomy does not prove every 6205 suffix is currently orderable.
NTNZZ = non-contact metal shield; LLB = non-contact rubber seal; LLU = contact seal; LLH = low-torque seal with a specially designed lip.LLH is not interchangeable with LLU merely because both are rubber sealing solutions. NTN's comparison gives LLH medium torque, better dust exclusion than LLB, good water proofing and much better high-speed capacity than LLU.
NSK6205DDU = rubber contact seals on both sides; NSK's designation guide distinguishes DDU (sealed) from VV (non-contact seals) and ZZ (shields).DDU identifies the seal category and sides, not a universal lip profile, elastomer compound, torque curve or water-ingress rating.
SKF2RSH = NBR contact seals on both sides; 2RSL = NBR low-friction seals; 2RZ = non-contact seals; 2Z = shields.SKF's 6205-2RSH/C3GJN product page labels the sealing type “Low-friction”, but the 2RSH designation remains a contact-seal code. Do not confuse it with the distinct 2RSL suffix.
FAG / Schaeffler6205-C-2HRS>V is explicitly listed as a Generation C bearing with contact seals on both sides.2HRS confirms the contact-seal category, not equivalence to another maker's seal lip, grease fill or operating envelope.

The hidden middle category matters: a two-way “shielded versus contact-sealed” buying choice is incomplete. JTEKT distinguishes non-contact sealed 2RU, contact 2RS/2RK and extremely light-contact 2RD. NTN separately distinguishes non-contact LLB, contact LLU and low-torque LLH. These are meaningful design categories because the published NTN comparison shows a trade-off: LLU has excellent dust proofing and very good water proofing, but higher torque and contact-limited speed; LLH reduces torque relative to LLU and retains stronger dust protection than LLB, while its water-proofing is rated “Good”, not “Very good”. This is a source-specific qualitative comparison, not a quantified ingress or torque test.

6205 exact-product cross-check: the following exact manufacturer products all have the 25 × 52 × 15 mm envelope and double-sided contact seals, but their published grease limiting speeds differ: Koyo / JTEKT 6205 2RS — 8,400 min⁻¹; NSK 6205DDU — 9,000 min⁻¹; SKF 6205-2RSH/C3GJN — 8,500 min⁻¹; FAG 6205-C-2HRS>V — 12,200 min⁻¹. These values are not a controlled seal-performance comparison. The exact variants also differ in other disclosed attributes: SKF is C3 / GJN; FAG is CN / P6 / GA14 / Generation C; NSK's listed 6205DDU is CN / P0; and the cited JTEKT product record does not disclose a matching grease identity, fill percentage or clearance suffix. The available sources do not establish identical test loads, thermal conditions, lubrication fill or speed-rating methodology. Therefore the speed figures cannot be used to rank seal friction or to infer that one contact-seal architecture is inherently faster.

Selection and substitution path: first decide whether the application needs a non-contact barrier, a light-contact / low-torque compromise, or a contact barrier for stronger dust and water exclusion. Then compare the exact manufacturer's construction drawing, seal material, lip geometry and contact arrangement. For high-speed or energy-loss sensitive duty, request a friction-torque curve at the intended speed, temperature and lubricant condition. For wet or washdown duty, request the actual ingress test method, pressure / exposure conditions and acceptance class; a generic “contact seal” label is not a waterproof rating. Confirm the factory grease identity, fill quantity or fill-code basis, operating-temperature range and limiting-speed definition on the exact ordered suffix.

RFQ and receiving checks: write the complete manufacturer designation, not only “6205-2RS equivalent”; require both-side seal confirmation, contact category, seal material, grease code and fill basis, temperature range, limiting-speed basis, and the manufacturer's drawing or technical declaration. On receipt, match the box and ring markings to the ordered full designation and request batch documentation where the seal material, grease or special low-torque execution is contract-critical. Do not infer these hidden attributes from the generic 6205 dimensions or from a reseller's suffix crosswalk.

Scope and limits: this is a functional-category comparison of manufacturer-published designations plus four exact 6205 product records. It does not establish that JTEKT 2RD, NTN LLH or SKF 2RSL is available as a 6205 variant in the cited product ranges; exact 6205 orderability for those special categories remains unverified. It does not establish a one-to-one equivalence among 2RS, DDU, 2HRS and 2RSH, a common seal test standard, quantified water/dust protection, seal torque, grease compatibility or application life. The speed figures are catalogue values for different complete bearing executions, not seal-only test results. Confirm the precise ordered suffix and application conditions with the originating manufacturer before substitution.

Sources: Koyo / JTEKT Ball & Roller Bearings, CAT. NO. BS004EN-2DS, Section 1-2, Table 1-1 (ZZ / 2RU / 2RS / 2RK / 2RD functional types) and Section 6-3 “Bearing number”, seal-code list (2RU, 2RS, 2RK, 2RD); Koyo / JTEKT official 6205 2RS product record (25 × 52 × 15 mm; 8,400 min⁻¹); NTN Handbook — Our industrial products and services at a glance, “Sealing concept”, printed pp. 21–22, Table “Overview of NTN standard seals” (construction, torque, dust, water and high-speed qualitative comparison; LLU / LLB / LLH / ZZ definitions); NSK Bearing Designation Systems, BD 03 / 2024, Table 3.3, printed pp. 23–24 (DDU / VV / ZZ) and Tables 3.11.1–3.11.2, printed pp. 36–37 (grease codes and fill ranges); NSK official 6205DDU product record (25 × 52 × 15 mm; contact seals; 9,000 min⁻¹); SKF Bearing Maintenance Handbook, PUB SR/P7 10001/1 EN, September 2011, “Designation system for rolling bearings”, printed p. 25 (2RSH / 2RSL / 2RZ / 2Z); SKF official 6205-2RSH/C3GJN product record (25 × 52 × 15 mm; 8,500 min⁻¹); Schaeffler official selected-product record for FAG 6205-C-2HRS>V, generated 2026-05-21 (contact seals, CN, P6, GA14, 12,200 min⁻¹).

6205 vs 6204 vs 6204 ZZ vs 6204 2RS — same-manufacturer series comparison

Nearest published designations in the same series. A manufacturer is named only when the evidence record identifies a bearing maker; otherwise the column says it is not identified. Source configuration and each field's publisher attribution remain separate. When more than one manufacturer appears, this is a cross-manufacturer catalog comparison, not an equivalence, interchangeability or common-source claim. Highlighted rows are the parameters that differ across these published records; unhighlighted rows have identical published values, not necessarily identical performance in service.

Parameter 6205 (this page)
Manufacturer: Koyo / JTEKT
Source configuration: open
6204
Manufacturer: Koyo / JTEKT
Source configuration: open
6204 ZZ
Manufacturer: Koyo / JTEKT
Source configuration: double metal shield
6204 2RS
Manufacturer: Koyo / JTEKT
Source configuration: double contact seal
Bore diameter (d) 25 mm
standard-model · jtekt.co.jp · Manufacturer-published specification
20 mm
standard-model · koyo.jtekt.co.jp · Manufacturer-published specification
20 mm
standard-model · koyo.jtekt.co.jp · Manufacturer-published specification
20 mm
standard-model · koyo.jtekt.co.jp · Manufacturer-published specification
Outside diameter (D) 52 mm
standard-model · jtekt.co.jp · Manufacturer-published specification
47 mm
standard-model · koyo.jtekt.co.jp · Manufacturer-published specification
47 mm
standard-model · koyo.jtekt.co.jp · Manufacturer-published specification
47 mm
standard-model · koyo.jtekt.co.jp · Manufacturer-published specification
Width (B) 15 mm
standard-model · jtekt.co.jp · Manufacturer-published specification
14 mm
standard-model · koyo.jtekt.co.jp · Manufacturer-published specification
14 mm
standard-model · koyo.jtekt.co.jp · Manufacturer-published specification
14 mm
standard-model · koyo.jtekt.co.jp · Manufacturer-published specification
Basic dynamic load rating (Cr) 17.5 kN
reference-manufacturer · jtekt.co.jp · Manufacturer-published specification · Basic dynamic load rating is a catalog reference used in bearing-life calculations; confirm equivalent load, speed, reliability and required service life for the application.
16 kN
reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Basic dynamic load rating is a catalog reference used in bearing-life calculations; confirm equivalent load, speed, reliability and required service life for the application.
16 kN
reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Basic dynamic load rating is a catalog reference used in bearing-life calculations; confirm equivalent load, speed, reliability and required service life for the application.
16 kN
reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Basic dynamic load rating is a catalog reference used in bearing-life calculations; confirm equivalent load, speed, reliability and required service life for the application.
Basic static load rating (C0r) 7.85 kN
reference-manufacturer · jtekt.co.jp · Manufacturer-published specification · Basic static load rating is a catalog reference; verify equivalent static load and the required static safety factor for the application.
6.65 kN
reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Basic static load rating is a catalog reference; verify equivalent static load and the required static safety factor for the application.
6.65 kN
reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Basic static load rating is a catalog reference; verify equivalent static load and the required static safety factor for the application.
6.65 kN
reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Basic static load rating is a catalog reference; verify equivalent static load and the required static safety factor for the application.
Fatigue load limit (Cu) — not published
Not published for this designation
0.51 kN
reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Fatigue load limit is a catalog reference, not a standalone allowable-load or service-life guarantee; verify application duty and lubrication conditions.
0.51 kN
reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Fatigue load limit is a catalog reference, not a standalone allowable-load or service-life guarantee; verify application duty and lubrication conditions.
0.51 kN
reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Fatigue load limit is a catalog reference, not a standalone allowable-load or service-life guarantee; verify application duty and lubrication conditions.
Limiting speed, grease 13000 min-1
reference-manufacturer · jtekt.co.jp · Manufacturer-published specification · Catalog limiting speed for grease lubrication, not an application operating recommendation. Confirm lubricant, temperature, load, sealing and duty conditions before selection.
15000 min-1
reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Catalog limiting speed for grease lubrication, not an application operating recommendation. Confirm lubricant, temperature, load, sealing and duty conditions before selection.
15000 min-1
reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Catalog limiting speed for grease lubrication, not an application operating recommendation. Confirm lubricant, temperature, load, sealing and duty conditions before selection.
9700 min-1
reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Catalog limiting speed for grease lubrication, not an application operating recommendation. Confirm lubricant, temperature, load, sealing and duty conditions before selection.
Limiting speed, oil 15000 min-1
reference-manufacturer · jtekt.co.jp · Manufacturer-published specification · Catalog limiting speed for oil lubrication, not an application operating recommendation. Confirm lubricant, temperature, load, sealing and duty conditions before selection.
17000 min-1
reference-manufacturer · koyo.jtekt.co.jp · Manufacturer-published specification · Catalog limiting speed for oil lubrication, not an application operating recommendation. Confirm lubricant, temperature, load, sealing and duty conditions before selection.

Not published for this designation

Not published for this designation

Each published cell carries its own parameter tier and publisher attribution; each column identifies the manufacturer only when the evidence record names one, plus the source configuration. A source publisher is not necessarily the supplying source for an order. Cross-manufacturer values are shown for catalog context only: they do not establish interchangeability, equivalent quality, common manufacturing origin or a preferred supply route. Compare values only within the stated parameter class, publisher, configuration and operating conditions. Industry-reference values are not manufacturer-specific. Confirm fit, load, speed, clearance, sealing and actual supplying source for your application in the quotation.

Applications and selection notes

Deep groove ball bearings are the default radial bearing for electric motors, fans, pumps, gearboxes, agricultural machinery and general industrial equipment. The single-row design carries radial load and a limited axial load in both directions, needs no adjustment after mounting, and runs at higher speeds than most alternative types of the same size.

In the sealed (2RS) and shielded (ZZ) executions, the bearing is lubricated for life and maintenance-free under normal operating conditions, which is why motor and appliance manufacturers standardise on them. In the open execution, the bearing is lubricated from the housing or shaft — the usual choice when the surrounding assembly provides filtration, re-lubrication or oil-bath lubrication.

How to read the specification table

Read the specification table against three limits. Boundary dimensions (bore, outside diameter, width) decide whether the bearing fits the shaft and housing — these are standardised designation-bound values and interchangeable across conforming manufacturers. Load ratings (Cr, C0r) describe different failure checks: Cr is used for rolling-fatigue life under dynamic load; C0r is the ISO 76 basic static rating tied to a defined contact-stress / permanent-deformation criterion, not a universal allowable working load.

Do not approve a bearing from C0r alone. For a deep-groove ball bearing, first convert the actual radial/axial load combination to the equivalent static load P0 using the exact maker’s X0/Y0 factors, then calculate s0 = C0r / P0. The required s0 is an application criterion, not a suffix or a universal constant: NTN’s Precision Rolling Bearings catalogue (Table 3.3) gives minimum values for ball bearings of 2 for quiet-rotation applications, 1.5 for impact-load applications and 1 for normal-rotation applications, and explicitly says vibration/shock requires a shock-load factor in P0 max. SKF’s 2018 general catalogue separately classifies rotating versus non-rotating duty, quiet-running requirement and shock severity in Table 5, and says to use the maximum load that can occur. These tables are not a common test or a directly transferable brand ranking; their application categories differ. For ordinary aligned arrangements, use the exact maker’s C0r, X0/Y0 and stated duty assumptions. Where shaft/housing tilt, misalignment, moment load or operating clearance materially changes rolling-element load sharing, the simplified ISO 76 C0/P0 check may miss the peak-loaded element: ask for an effective static safety-factor calculation using ISO 17956:2025 or an equivalent documented internal-load-distribution method. ISO 17956 adds tilt/misalignment, operating clearance and internal load distribution; it checks static deformation only, not fatigue life, false brinelling, wear or microspalling. In the RFQ, provide peak radial and axial loads, shock duration/direction, rotation state, required quietness, operating clearance, shaft/housing misalignment and moment load; request the maker’s P0 factors, selected s0 basis and calculation assumptions. Do not use Cr as a substitute for this static check or treat a passing basic C0/P0 ratio as proof for a tilted or moment-loaded assembly.

Limiting speeds are catalog values established for the manufacturer’s execution, clearance and lubrication; they are not an operating recommendation for your application. Sealed and shielded executions, heavy fits, elevated temperature or misalignment all reduce the usable speed. Confirm the speed and clearance choice against your actual conditions before ordering — the internal-clearance class in particular should follow fit, temperature and speed, not a default.

Cross reference: see how 6205 relates to its ZZ / 2RS executions and the rest of its series — boundary dimensions first, execution and clearance confirmed per application on the bearing cross reference page.

Related engineering knowledge

Background reading that supports the selection decision on this page — failure modes, seal trade-offs and lubrication behavior. These articles explain the engineering; the specifications and supply commitments live on this page and in the quotation.

6205 — buying questions

What does the designation 6205 mean?

6205 is a standard boundary-dimension designation: the dimension series fixes the outside diameter and width proportions, and the bore code fixes the bore diameter — 25 mm for this bearing. Two bearings carrying the same designation from conforming manufacturers are dimensionally interchangeable; execution (seals, clearance class, cage) is the part that can differ, so state the execution you need when you request a quotation.

Are the catalog load rating and speed of 6205 enough for my application?

The table lists Basic dynamic load rating (Cr) = 17.5 kN and grease-lubricated limit 13000 min-1 and oil-lubricated limit 15000 min-1. The load rating is the starting point of a life calculation, and each speed is a catalog limit for the manufacturer’s execution, not an application operating recommendation. Seals, fits, temperature and lubrication all affect the usable speed in a real assembly. Both lubricant-specific limits are listed; compare each only under its stated lubricant and manufacturer execution. Send the application conditions with your inquiry and we confirm suitability before quoting; do not size from the catalog speed alone.

What information do you need to quote 6205?

Four things, in one message: the designation (and execution — seals, clearance class, precision class, if not standard), the quantity, the destination country, and any documents you require. Application conditions such as speed, load direction and temperature are welcome and let us verify the execution instead of assuming it. Quotation, lead time and the exact document set come back in writing.

Ordering & documentation

Documents

The documents available for 6205 depend on the actual supplying source and order. State any required export, origin, material or inspection documents in your inquiry; the available document set is confirmed in writing with the quotation.

Quotation

To quote 6205, send: the designation and required execution, quantity, destination country, and any required documents. Adding the application conditions (speed, load direction, temperature, fit) lets us confirm the execution and clearance class instead of quoting blind.

Sample & supply

If you need an evaluation sample of 6205, state the required quantity and timing. Sample feasibility, source, price and dispatch timing are confirmed in the quotation; sample availability is not assumed from the standard designation alone.

Lead time for this designation and quantity is confirmed in the quotation against the actual supplying source and availability. Any applicable certificates and quality documents are confirmed for the actual supplying source and product; available documents are stated in the quotation.

Storage & shipping

Store bearings flat in their original, unopened packaging in a dry indoor area away from temperature swings. Confirm the actual preservation method, packaging, marking and transport protection for the supplying source and order before shipment. Do not rotate a bearing through its rolling elements during handling or mounting.

6205 speed ratings — separate the mechanical limit from the thermal reference and check the load basis

Buyer conclusion: a catalogue speed is not a single, universal permissible RPM. First identify whether the number is a grease/oil limiting speed or a thermal reference speed; then check the manufacturer's load-ratio and lubrication assumptions. For an open 6205, SKF's thermal reference speed is an ISO-condition starting point, not a mechanical ceiling. For a contact-sealed 6205, SKF does not publish an ISO reference speed: the seal-related mechanical limit generally governs. Do not compare an SKF thermal reference number directly with an NSK grease/oil limiting-speed number.

QuestionSKF — PUB BU/P1 17000/1 ENNSK — CAT. No. E1103BBuyer consequence
What does the table speed represent? Reference speed = thermal equilibrium under standardized heat generation / dissipation; limiting speed = mechanical constraints such as cage strength/guidance, rolling-element forces, seals and lubricant Grease and oil limiting speeds are empirical continuous-operation limits; the oil column is specified for forced-circulation oil lubrication in this catalogue Match the metric and lubrication method before comparing values; SKF reference speed is not the same kind of number as NSK limiting speed
Normal-load basis ISO 15312 reference case for radial bearings: P = 0.05 C₀; this is a thermal reference condition, not SKF's mechanical limit For ball bearings, normal-load applicability is C/P ≥ 13 and Fₐ/Fᵣ ≤ approximately 0.2 Do not treat P/C₀ and P/C as the same load ratio; C₀ is the static rating, C is the dynamic rating
When does load adjustment enter? SKF recommends adjusted reference speed using actual load and lubricant viscosity; that adjustment still omits the application's actual heat dissipation Correct the grease/oil limiting speed when P exceeds approximately 7% of C or Fₐ exceeds 20% of Fᵣ, using the relevant correction-factor curves Ask for the manufacturer's calculation, not a generic percentage haircut or a cross-brand correction factor
Seal / lubrication boundary ISO reference conditions apply to open bearings; no ISO reference conditions are provided for sealed bearings. Contact-sealed bearings generally use limiting speed as the maximum Grease and oil limits are separate; rubber contact-seal limits are governed mainly by seal sliding speed at the inner-ring circumference Do not transfer an open-bearing thermal reference to 6205-2RSH / 6205DDU or another contact-sealed execution

The hidden overlap in NSK's load conditions

NSK's catalogue states that the tabulated grease/oil limiting speeds apply to standard-design ball bearings under normal load where C/P ≥ 13. The same section says to apply a speed correction when P is greater than approximately 0.07C. These statements are not mutually exclusive: the approximate interval 13 ≤ C/P < 14.29 satisfies the stated normal-load envelope while also crossing the correction trigger. The value 14.29 is an arithmetic boundary derived from 1/0.07, not a separately published NSK threshold; because NSK says “approximately 7%”, do not treat the boundary as an exact contractual cutoff. Axial load also triggers correction independently when Fₐ/Fᵣ exceeds 0.20.

Why the two manufacturers' ratios cannot be merged: NSK's P/C comparison uses the basic dynamic load rating C. SKF's ISO thermal reference case uses P = 0.05 C₀ for radial bearings, where C₀ is the basic static load rating. These ratios answer different questions and use different denominators. A buyer who sends only “load is 5% of rating” has not supplied enough information to apply either method.

SKF's thermal reference conditions are deliberately narrow

For open radial bearings, SKF's ISO reference basis includes P = 0.05 C₀, ambient 20 °C, nominal temperature rise 50 °C, mineral oil ISO VG 32 without EP additives, clean conditions, sufficient operating clearance, horizontal shaft, rotating inner ring and stationary outer ring, and predefined heat dissipation. The ISO reference is also stated to apply to grease only when the grease has a lithium thickener and mineral base oil with viscosity 100–200 mm²/s; start-up temperature peaks may require running-in. SKF says to adjust for actual load and lubricant viscosity, but that adjustment does not include actual application heat dissipation. A detailed thermal analysis is required to include it.

The mechanical limiting speed is a separate constraint. For open ball bearings, SKF says to use the lower of the adjusted thermal reference speed and the mechanical limiting speed. For contact-sealed bearings, no reference speed is listed and the limiting speed typically determines the maximum. If a design proposes operation above a reference or limiting speed, SKF calls for detailed thermal analysis and review of cooling, operating-clearance reduction, housing fit / non-locating-ring axial movement, seat precision, cage execution and lubricant.

RFQ and substitution checks

  • State the exact manufacturer and full 6205 designation, including open / ZZ / contact-seal execution, clearance, cage and grease suffix.
  • Provide actual radial load, axial load, duty cycle and speed; require the supplier to calculate equivalent load P using that manufacturer's method and state whether C or C₀ is used in each ratio.
  • For NSK, ask for the corrected grease/oil limiting speed and the Fig. 5.1 / Fig. 5.2 correction factors when P/C or Fₐ/Fᵣ crosses its stated trigger; confirm whether the oil value assumes forced circulation.
  • For SKF, request both the adjusted reference speed and mechanical limiting speed, the assumed lubricant viscosity and the thermal / heat-dissipation basis; do not accept the reference speed alone as the operating limit.
  • Specify lubricant type and viscosity at operating temperature, grease fill / replenishment method, oil bath or circulation/jet method, ambient and bearing temperatures, shaft/housing material and fit, operating clearance and cooling arrangement.
  • For contact seals, confirm the exact manufacturer's seal-specific speed limit; an open-bearing thermal reference is not transferable.

Scope and limits: this is a comparison of manufacturer speed-rating methods for 6205-class selection, not a calculation of an actual permissible speed. The NSK correction curves must be read for the actual bearing type and load ratios; this page does not invent a correction factor or calculate a new RPM. SKF's adjusted reference speed is not a complete thermal model because actual application heat dissipation is not included. No bearing clearance, fit, cage, grease, cooling or batch-specific speed capability is inferred from the generic method descriptions. The SKF reference-speed basis is for open bearings; do not apply it to contact-sealed 6205 variants. Confirm the current exact product record and application-specific manufacturer approval before treating a speed as an acceptance limit.

Sources: SKF, Rolling bearings, PUB BU/P1 17000/1 EN, October 2018, Section B.5 “Operating temperature and speed”, printed pp. 135–136 (reference vs limiting speed; ISO 15312 conditions; adjusted reference speed; contact-seal boundary; above-rating thermal, clearance and fit checks). Open SKF catalogue PDF. NSK, Rolling Bearings for Industrial Machinery, CAT. No. E1103B, Part A, Section 5.1 / 5.1.1 / 5.2, Table 5.1, printed pp. A 098–A 099 (grease/oil limiting-speed definitions, C/P and Fₐ/Fᵣ normal-load envelope, approximately 7% C and 20% Fᵣ correction triggers, correction curves, ISO 15312 thermal reference conditions). The PDF does not display a publication/revision date; catalogue identifier E1103B is retained and the official PDF was accessed 2026-11-25. Open NSK catalogue PDF.

6205 — a higher dynamic rating does not mean the same increase in static capacity or real service life

Buyer conclusion: the same 25 × 52 × 15 mm open 6205 envelope does not guarantee the same published load ratings. In the four original-manufacturer records below, basic dynamic rating C spans 14.8–17.5 kN, while basic static rating C₀ stays within 7.8–7.9 kN. A buyer selecting only by C can miss a separate static/shock-load constraint; a buyer translating C directly into a guaranteed service-life advantage can overstate what the catalogue data prove.

Original manufacturer / exact open executionDimensionsBasic dynamic CBasic static C₀Fatigue limitWhat is actually disclosed
SKF — 6205, open25 × 52 × 15 mm14.8 kN7.8 kNNot listed in the cited 6205 product rowSKF 2024 catalogue, standard single-row Conrad execution
NSK — 6205, open25 × 52 × 15 mm15.4 kN7.85 kNNot listed on the cited product record9 balls, Dw 7.938 mm, pressed-steel cage
Koyo / JTEKT — 6205, open25 × 52 × 15 mm17.5 kN7.85 kNCu = 0.550 kNf₀ = 13.9; grease/oil speed fields are separate and are not used in this load comparison
NTN / SNR — 6205-SNR, open25 × 52 × 15 mm14.8 kN7.9 kNCu = 0.36 kNCN clearance, pressed-steel cage; reference thermal speed and mechanical limit are separately listed

What the cross-source comparison changes

The four records agree on the nominal envelope, but not on C. JTEKT's published C is about 18.2% above SKF's and 13.6% above NSK's. By contrast, the published C₀ values differ by only about 1.3% from the lowest to the highest. This is not a contradiction: C and C₀ answer different questions. C is used in rolling-fatigue basic-life calculations; C₀ is used to check static contact deformation and shock/peak-load safety. The two checks must be made independently.

For a ball bearing, the basic rating-life relationship is L₁₀ = (C/P)³, where P is the manufacturer's equivalent dynamic bearing load. If—and only if—the same P, load direction/spectrum, reliability basis and calculation scope are applied, the published C values imply a conditional basic-life ratio of about 1.65 for JTEKT versus SKF and 1.47 for JTEKT versus NSK. These are arithmetic comparisons of catalogue inputs, not endurance-test results and not a prediction that a delivered JTEKT bearing will last 65% or 47% longer in a machine.

That qualification matters because the product pages do not disclose a common internal-geometry drawing, common test programme or shared application load spectrum. The higher C cannot be attributed to a specific ball count, groove geometry, material improvement or manufacturing process from these public records alone. Nor does it mean the static safety factor rises by the same percentage: for static loading the buyer must calculate P₀ and compare C₀/P₀ using the exact manufacturer's static-load method.

Fatigue limit and standard-version boundary

JTEKT publishes Cu = 0.550 kN and defines the fatigue load limit as the bearing load at which the fatigue stress limit is just reached at the most heavily loaded raceway contact. SNR publishes Cu = 0.36 kN, but its product page does not identify the calculation edition or provide a common test basis. The SKF and NSK records cited here do not list a fatigue-limit value for the exact open 6205 row. A missing public field is not zero and is not proof that a manufacturer cannot supply it. Do not rank all four bearings by Cu/Pu when the field is not disclosed consistently.

There is also a documentation-version issue to resolve at RFQ stage. JTEKT's general basic-dynamic-rating explanation still says its tabulated C values are prescribed by ISO 281:1990 and subject to change with later ISO editions; the same JTEKT page separately describes modified rating life under ISO 281:2007 / JIS B 1518:2013, including reliability, lubrication, contamination and Cu. SKF's Deep groove ball bearings catalogue, Publication 100-700, Version 8/2024, still cites ISO 281:1990 and Amendment 2:2000 in its rating-life explanation. ISO's published record identifies ISO 281:2007 as Edition 2 (2007-02), reviewed and confirmed in 2021; ISO/TR 1281-1:2021 explains that the 2007 edition incorporated the modified-life method for lubrication, contamination and fatigue load limit. This documentation mismatch does not by itself invalidate any current product rating, but it means the buyer should ask which edition and manufacturer method govern the quoted basic rating and modified-life calculation.

RFQ and substitution checks

  • Specify the exact original manufacturer and full execution: open / shielded / contact-sealed, internal design generation, clearance, cage and lubricant suffix. Do not request only “6205 equivalent”.
  • Provide the actual radial and axial loads, peak/shock loads, duty cycle, speed and target reliability. Ask each manufacturer to state the equivalent dynamic load P and static equivalent load P₀ using its own static-load method.
  • Request C, C₀ and Cu/Pu as separate fields, with the governing ISO/JIS/ABMA edition, product design assumptions and whether the values are standard or special execution ratings.
  • Ask for both L₁₀ basic life and, where the application requires it, modified life Lₙₘ / aISO with the assumed lubricant viscosity, contamination level, operating temperature and fatigue-limit input.
  • For shock, stationary, slow-oscillating or short-duration peak loads, require a separate C₀/P₀ static-safety check; do not accept a higher C as a substitute.
  • At receiving, match the bearing and package marking to the approved full designation and the quoted load-rating sheet. A same-size bearing or a supplier's “equivalent” statement is not evidence of equal internal design or life.

Scope and limits: this is a cross-source comparison of the cited open 6205 product records, not a common-condition performance test or brand ranking. The conditional L₁₀ ratios use the basic ball-bearing exponent p = 3 and assume equal P and equal calculation scope; they are not measured lives. The four records do not provide a common internal-design drawing, fatigue-limit disclosure, reliability test or application calculation. Do not approve a substitute from the table alone. Obtain current order-specific data and manufacturer application confirmation for the actual load spectrum, speed, lubrication, fit, clearance and temperature.

Sources: SKF, Deep groove ball bearings, Publication 100-700, Version 8/2024, printed p.41, Table e2, row “6205” (25 × 52 × 15 mm; C = 14,800 N; C₀ = 7,800 N); Section “Bearing life”, printed pp.14–18 (C/C₀ roles, 90% basic-life basis, L₁₀ equation and SKF modified-life explanation). Open SKF catalogue. NSK, official “6205 Series” product record, specification fields (25 × 52 × 15 mm; Cr = 15,400 N; C₀r = 7,850 N; 9 balls, Dw = 7.938 mm; open, pressed-steel cage; accessed 2026-11-25). Open NSK 6205 record. Koyo / JTEKT, official 6205 Product record, “Specification data” (25 × 52 × 15 mm; Cr = 17.5 kN; C₀r = 7.85 kN; Cu = 0.550 kN; accessed 2026-11-25). Open JTEKT 6205 record; JTEKT Basic Bearing Knowledge, Section 5-2-1 to 5-2-4 (basic C definition; L₁₀ at 90% reliability; modified-life factors; Cu definition; ISO 281:1990 / 2007 references). Open JTEKT service-life guidance. NTN / SNR, official e-shop “6205 - SNR” product record (open 25 × 52 × 15 mm; C = 14.8 kN; C₀ = 7.9 kN; Cu = 0.36 kN; CN; accessed 2026-11-25). Open NTN-SNR 6205 record. ISO, ISO 281:2007 — Rolling bearings — Dynamic load ratings and rating life, Edition 2, February 2007, official status/abstract (basic dynamic ratings, 90% basic rating life and modified-life inputs; reviewed and confirmed 2021). Open ISO 281:2007 record. ISO, ISO/TR 1281-1:2021, second edition, May 2021, historical note printed p.5 and Sections 1, 6 and 8 (relationship between ISO 281:1990 and 2007; explanatory basis for C and L₁₀). Open ISO/TR 1281-1:2021 preview.

6205-CM — the 5–12 μm catalogue range is not automatically the gauge-reading acceptance range

Buyer conclusion: NTN, NSK and Koyo/JTEKT independently publish the same 5–12 μm initial radial-clearance band for a 25 mm-bore deep-groove motor bearing with CM clearance. Do not treat that initial band as a universal gauge-reading acceptance band. NSK explicitly states that CM measured-clearance increase equals the CN correction; at 49 N for an 18–50 mm bore, that is 5 μm, giving a derived NSK reading interval of 10–17 μm. JTEKT only refers its CM table to Table 10-2 without identifying which correction column applies to CM; NTN's cited public CM table gives no CM-specific correction. For JTEKT and NTN, the exact CM reading rule remains to be confirmed with the manufacturer or supplier.

Cross-manufacturer evidence for 6205-CM

Original manufacturerApplicable bore bandCM initial radial clearanceMeasuring-load disclosure
NTNOver 24 / up to 30 mm5–12 μmTable 8.11 does not state a correction load or reading adjustment
NSKOver 18 / up to 30 mm5–12 μm49 N; explicitly says CM measurement increase equals CN correction: 5 μm for 18–50 mm
Koyo / JTEKT18–30 mm5–12 μmTable 10-7 points to Table 10-2, but does not explicitly identify which correction column applies to CM

The three independent manufacturer tables agree on the initial CM band for a 25 mm bore. Their row labels differ, but d = 25 mm falls inside all three ranges. This supports comparison of the published initial-clearance interval; it does not prove identical internal geometry, batch distribution, inspection procedure or installed operating clearance.

Why the measuring load changes incoming inspection

NSK's Industrial Motor Bearings catalogue explicitly says the radial-clearance increase for CM bearings caused by measuring load equals the CN correction amount in its general clearance table. For a 25 mm bore, the cited 49 N measuring load and 18–50 mm CN correction amount produce +5 μm. JTEKT's Table 10-7 points to Table 10-2 for measurement-load adjustment, but Table 10-2 lists correction amounts by C2/CN/C3/C4/C5 and does not explicitly map CM to one of those columns. NTN's Table 8.11 lists CM limits but no CM-specific measuring-load correction. Those two public-source gaps must remain open; do not silently infer a CM correction from the CN column.

Derived NSK reading interval only (not an original catalogue clearance class): 5–12 μm initial CM clearance + 5 μm correction = 10–17 μm indicated reading under NSK's stated 49 N method. This is not a universal CM gauge band and must not be applied to JTEKT or NTN without written confirmation of their CM correction convention. Always record whether the supplier's result is raw or already corrected.

Fit and operating-clearance boundary

NSK's Industrial Motor Bearings catalogue recommends a k5 shaft fit for the 18–30 mm CM deep-groove motor-bearing row. Its housing recommendation depends on outer-ring axial movement: H6/H7 where the outer ring must move axially, or JS6/JS7 (J6/J7) where it does not. These are NSK catalogue recommendations, not universal fit instructions for every 6205 installation; confirm load direction, shaft/housing material, thermal state and axial locating arrangement before specifying them.

JTEKT separately defines operating clearance as S = So − (Sf + St1 + St2) + Sw: initial clearance So is reduced by fit and temperature effects, with a load-related term Sw. Therefore, even a correctly measured 5–12 μm initial CM bearing does not by itself establish the installed or hot-running clearance. The buyer must provide actual shaft and housing fits, ring temperatures and the axial locating/floating arrangement before an operating-clearance conclusion can be made.

RFQ and incoming-inspection requirements

  • Identify the original manufacturer and exact execution: 6205-CM, 25 × 52 × 15 mm; do not treat CM as proof of complete cross-brand interchangeability.
  • Specify the shaft and housing tolerance, whether the outer ring must move axially, and which ring is locating or floating.
  • Require the supplier to report the measuring load, measurement method, temperature, raw reading and whether a correction has already been applied.
  • For NSK/JTEKT measurements using 49 N, interpret the reading using the respective catalogue correction; do not reject a 13 μm reading simply because it is above the uncorrected 12 μm catalogue maximum.
  • For NTN, do not assume the same 49 N / +5 μm convention from its published Table 8.11; request written confirmation from the actual supplier/manufacturer.
  • Record pre-mounting and post-mounting clearance separately. Do not present initial CM clearance as a guarantee of hot-running clearance.

Source references

NTN, Ball and Roller Bearings, CAT. No. 2203/E, Table 8.11 “Radial internal clearance of bearings for electric motor” (CM, 24–30 mm: 5–12 μm; example suffix 6205 ZZ CM), plus NTN official 6205CM product record (25 × 52 × 15 mm, CM): Open NTN catalogue PDF · Open NTN 6205CM product record.

NSK, Industrial Motor Bearings, CAT. No. E1289C, printed pp.30–31, §4 “Radial Internal Clearance” (CM table; 49 N correction; k5 shaft and conditional housing fits), plus official 6205CM product record: Open NSK catalogue PDF · Open NSK 6205CM product record.

Koyo / JTEKT, Basic Bearing Knowledge, “Operating clearance”, Tables 10-1, 10-2 and 10-7 (CM 18–30 mm: 5–12 μm; 49 N / 5 μm correction; operating-clearance relationship): Open JTEKT operating-clearance reference.

Boundary: the 10–17 μm reading interval is derived only from NSK's explicit CM-to-CN correction rule at 49 N. JTEKT's exact CM correction mapping and NTN's CM correction remain unconfirmed in the cited public material. None of these intervals is a batch test result or an installed-clearance guarantee.

6205-CM versus 6205-C3 — clearance-class substitution boundary

Buyer decision: a 6205-C3 is not a clearance-equivalent replacement for a 6205-CM merely because both share the 6205 envelope (25 × 52 × 15 mm). At the 25 mm bore band, the three compared makers publish CM = 5–12 μm and C3 = 13–28 μm. The intervals do not overlap: the C3 minimum is 1 μm above the CM maximum. C3 is a larger-clearance execution, not a higher grade of CM.

Original manufacturerCM initial clearanceC3 initial clearance49 N measurement evidence
NSK5–12 μm (18–30 mm, Table 8.14.1)13–28 μm (24–30 mm, Table 8.10)C3 +6 μm; CM explicitly uses CN correction +5 μm
Koyo / JTEKT5–12 μm (18–30 mm, Table 10-7)13–28 μm (24–30 mm, Table 10-2)C3 +6 μm; CM correction column is not explicitly identified by Table 10-7
NTN5–12 μm (24–30 mm, Table 8.11)13–28 μm (24–30 mm, Table 8.8 / Table 9.1)C3 +6 μm at 49 N; CM-specific correction not published in the cited table

Cross-source result: the three manufacturers agree on the nominal initial CM and C3 intervals for the 25 mm bore, so the key finding is not a brand ranking. It is the consistent, non-overlapping boundary between two different clearance executions, plus a manufacturer-specific gap in how CM measurement correction is documented. The same 6205 dimensions therefore do not establish clearance substitution.

Derived 49 N readings, kept separate from catalogue limits: C3 = 13–28 μm + 6 μm = 19–34 μm for the published C3 correction method (NSK, JTEKT and NTN). For CM, NSK explicitly supports 5–12 μm + 5 μm = 10–17 μm; JTEKT and NTN do not provide an equally explicit CM-to-correction mapping in the cited sources. Do not fill that gap by assumption.

Substitution implication: replacing a CM design with C3 can leave a larger initial clearance; replacing C3 with CM can leave less clearance available after mounting. Whether either change is acceptable depends on actual shaft/housing interference, ring-temperature difference, operating speed/load and the required running clearance. Recalculate the installed/operating clearance; do not approve either substitution from the designation or initial-clearance table alone.

  • If the drawing or original specification requires CM, do not accept C3 as an automatic equivalent. Require a documented engineering deviation and recalculation of operating clearance.
  • If a supplier offers CM in place of C3, verify the resulting clearance after the actual fits and thermal conditions; do not assume the smaller CM interval will retain adequate running clearance.
  • In RFQ and incoming inspection, request exact maker and suffix, initial-clearance class, measurement force, measurement method, temperature, raw reading, correction rule and whether the reported value is corrected.
  • For JTEKT and NTN CM, obtain written confirmation of the CM measurement-load correction before setting a numeric gauge acceptance limit. Do not copy NSK's correction rule across manufacturers.

Sources for the CM / C3 comparison

NSK, Rolling Bearings for Industrial Machinery, CAT. No. E1103C Part A: Table 8.10 “Radial Internal Clearances in Deep Groove Ball Bearings”, printed p. A-169 (24–30 mm C3 13–28 μm; 49 N C3 correction +6 μm); Table 8.14.1 “Deep Groove Ball Bearings for Electric Motors”, printed p. A-170 (18–30 mm CM 5–12 μm; CM measurement-load increase equals CN correction): Open NSK technical catalogue.

Koyo / JTEKT, Basic Bearing Knowledge — Operating clearance, Table 10-2 (24–30 mm C3 13–28 μm; 49 N C3 correction +6 μm) and Table 10-7 (18–30 mm CM 5–12 μm; measurement-load adjustment refers back to Table 10-2 but does not identify a CM correction column): Open JTEKT clearance tables.

NTN, Ball and Roller Bearings, CAT. No. 2203/E, Table 8.8 “Radial internal clearance of deep groove ball bearings”, printed p. A-92 (24–30 mm C3 13–28 μm); Table 8.11 “Radial internal clearance of bearings for electric motor”, printed p. A-95 (24–30 mm CM 5–12 μm; suffix example 6205 ZZ CM): Open NTN catalogue. NTN, Rolling Bearings Handbook, CAT. No. 9012-II/E, §9.1, Tables 9.1 and 9.2, printed p. 45 (24–30 mm C3 13–28 μm; 18–50 mm / 49 N C3 correction +6 μm): Open NTN handbook.

Comparability limit: the initial radial-clearance intervals are comparable because all three sources specify deep-groove ball bearings and the 25 mm bore falls within the stated bands. The CM measurement correction is not fully comparable: only NSK explicitly maps CM to the CN correction in the cited source. No cross-maker installed-clearance approval, batch measurement or operating-life guarantee is established.

6205-C3 — the initial clearance class does not determine hot-running clearance

Buyer conclusion: a 6205-C3 marking identifies an unmounted clearance group; it does not guarantee positive clearance after the shaft and housing fits are applied or after the bearing reaches operating temperature. JTEKT and NSK both separate the reduction caused by fits from the further reduction caused by ring-temperature differences, but their published calculation approaches expose different inputs. SKF independently states that the initial clearance must accommodate interference fits and operating temperature, and that a temperature difference above 10 °C between rings is a reason to consider C3 in electric-machine applications. Therefore, do not approve a 6205-C3 replacement from the suffix alone: request the exact shaft/housing fit calculation and the inner-ring, rolling-element and outer-ring temperature assumptions.

What the independent sources actually calculate

Source / methodFit-related reductionTemperature-related reductionBuyer consequence
Koyo / JTEKT — Operating clearance, Table 10-1Uses the actual interference and bearing/shaft/housing geometry in the fit-reduction term Sf.Separates inner-ring versus outer-ring temperature and rolling-element versus outer-ring temperature: St1 + St2 = α·Di·t1 + 2α·Dw·t2.Do not collapse the two temperature differences into one ring-temperature number when the rolling elements run hotter than the outer ring.
NSK — Rolling Bearings for Industrial Machinery, §8.2.2States that clearance reduction is approximately 70–90% of interference; the amount depends on bearing type/size and shaft/housing design.Uses δt = α·Δt·De, with De ≈ 1/5(4D + d) for ball bearings; Δt is the inner/outer-ring temperature difference.The 70–90% fit rule is an approximation, not a universal exact correction. The thermal estimate is tied to the NSK raceway-diameter approximation and ring-temperature difference.
SKF — Rolling bearings in electric motors and generators, “Bearing internal clearance”Identifies inner-ring expansion from shaft interference and outer-ring compression from housing interference as separate initial-clearance allowances.Requires allowance for the inner/outer-ring temperature difference, including start-up conditions; recommends considering C3 above a 10 °C ring-temperature difference in the stated electric-machine context.This is application guidance, not a universal C3 trigger for every bearing or duty. It does not supply a 6205-specific fit/temperature calculation.

Cross-source interpretation — where the methods are not interchangeable

JTEKT explicitly separates two thermal contributions: the inner-ring/outer-ring difference and the rolling-element/outer-ring difference. NSK's published simplified equation uses one inner/outer-ring temperature difference and an approximate ball-bearing raceway diameter. These are not identical input models. If the rolling elements have a distinct temperature from the inner ring, substituting NSK's single Δt into JTEKT's two-term expression, or vice versa, changes the assumptions rather than merely changing notation. SKF's electric-machine guidance supports the practical importance of the temperature difference but does not resolve the numerical difference between the two calculation models.

The useful boundary is therefore not that one manufacturer's formula is universally more accurate. The sources do not provide a same-6205, same-fit, same-temperature validation test. Instead, they show why a clearance calculation must name its model and temperature inputs. A generic statement such as “C3 compensates for tight fit and heat” is incomplete: the actual interference, ring support geometry, housing material, start-up temperature transient and rolling-element temperature can change the result.

For a 6205, the nominal envelope is 25 × 52 × 15 mm, but that alone is insufficient to calculate fit reduction. A 25 mm bore does not disclose the actual shaft tolerance, achieved interference, shaft material or hollow-shaft stiffness; the 52 mm outside diameter does not disclose housing-bore tolerance, housing material or wall thickness. The SKF 10 °C guidance is specific to the cited electric-machine application text and must not be turned into a general pass/fail threshold.

RFQ, installation and acceptance checks

  • Identify the exact manufacturer and full 6205 execution, including C3, cage, seal/shield and lubricant suffix; confirm that the offered product is the same open/sealed design as the approved position.
  • Provide the shaft and housing material, nominal dimensions, tolerance classes, measured dimensions, surface finish, hollow-shaft dimensions and housing wall geometry.
  • Ask the manufacturer to state the fit-induced clearance reduction method and inputs; do not accept a generic 70–90% interference estimate as a batch measurement.
  • State the expected inner-ring, rolling-element and outer-ring temperatures separately, including start-up and steady-state conditions. Ask the manufacturer to identify whether its method uses one ring-temperature difference or separate rolling-element and ring terms.
  • Record the measured initial clearance, the measuring load and any measurement-load correction separately from calculated residual clearance and calculated effective/operating clearance.
  • Do not treat a C3 marking, a catalogue temperature note or a calculated slightly negative value as a universal approval. Confirm the target operating-clearance range with the bearing manufacturer for the actual load, speed, lubrication and thermal cycle.

Scope and limits: this section is selection and RFQ guidance for the 6205 deep-groove-ball-bearing envelope. It compares published calculation assumptions; it is not a common-condition test, a worked clearance result or approval of any specific shaft/housing fit. JTEKT's formula contains a rolling-element temperature term that NSK's cited simplified equation does not separately expose; the sources do not establish that the methods produce equal results under every thermal field. SKF's greater-than-10 °C statement is limited to the cited electric-machine guidance. No buyer shaft/housing drawing, measured interference, ring/ball temperature history, load spectrum or start-up transient was supplied. Do not infer a guaranteed operating clearance, service life or brand interchangeability from this comparison.

References: Koyo / JTEKT, Basic Bearing Knowledge, “Operating clearance”, Table 10-1 and equations for fit and temperature reductions: JTEKT operating-clearance method; NSK, Rolling Bearings for Industrial Machinery, CAT. No. E1103C, §8.2.2, fit reduction and Eq. (8.8)–(8.9): NSK catalogue Part A PDF; SKF, Rolling bearings in electric motors and generators, “Bearing internal clearance”, initial-clearance allowances and 10 °C guidance: SKF electric-motor bearing guide PDF.

6205 axial load — a satisfactory P₀ / C₀ check does not prove the load stays inside the raceway shoulder

Buyer conclusion: for a single-row deep-groove 6205, three checks answer different questions. Dynamic equivalent load P estimates fatigue life. Static equivalent load P₀ compared with C₀ screens permanent-deformation risk. Allowable axial load Fₐ max checks whether the ball-to-raceway contact ellipse remains within the raceway shoulder. Passing the first two does not automatically pass the third. A calculation that stops at C₀ / P₀ can therefore approve an axial-load case that still needs a separate shoulder-contact check.

Why the published methods are not one interchangeable limit

Original manufacturerPublished methodHidden condition or boundaryBuyer interpretation
SKFFor single-row deep-groove ball bearings under pure axial load, the published general limit is Fₐ ≤ 0.5 C₀. SKF reduces this to 0.25 C₀ for small bearings with d ≤ 12 mm and light series 8, 9, 0 and 1.This is a manufacturer selection limit, not the same calculation as an explicit contact-ellipse geometry result. A 6205 is a 25 mm bore, series 62 bearing, so the stated small/light exceptions do not describe this example.SKF 6205 lists C₀ = 7.8 kN. Applying the SKF pure-axial rule gives a derived screening value of 0.5 × 7.8 = 3.9 kN. This is the result of that SKF rule only, not a cross-brand approval value or a substitute for checking the actual load case.
NSKNSK defines allowable axial load as the limit at which the contact ellipse reaches and passes over the raceway groove shoulder as axial load changes the contact angle. Its calculation uses internal geometry, ball count, contact angle and contact-ellipse dimensions. Figure 4.25 includes a 6205 curve against initial contact angle.NSK states that the contact ellipse may pass over the shoulder even when axial load is below the limit derived from static equivalent load P₀. It also states that allowable load cannot be determined without the bearing internal specifications.Do not infer the 6205 allowable axial load from C₀ or a static safety factor alone. Request the exact execution calculation or the applicable NSK value for its internal design and clearance.
NTNNTN publishes a separate allowable-axial-load chart for deep-groove bearings by series and bore diameter. Its physical criterion is the contact ellipse exceeding the raceway shoulder.The chart calculation uses the median of CN radial clearance and representative values. NTN labels these technical-data values as calculated and not guaranteed, and asks users to consult NTN Engineering for other types and sizes.The chart is a screening reference for the stated CN basis, not a guaranteed 6205-C3 or special-execution limit. Do not read a graph value as a batch rating or transfer it to a different clearance class.

The hidden distinction: load-life arithmetic versus contact geometry

JTEKT describes dynamic equivalent load P as a theoretical constant load that gives the same bearing service life as the actual combined radial and axial load. For a single-row radial bearing, when Fₐ / Fᵣ is at or below e, its calculation takes X = 1 and Y = 0, so P = Fᵣ. That statement is about the life-equivalent load calculation. It does not say axial load is physically unlimited whenever it is omitted from P. JTEKT also notes that the displayed equations assume zero operating internal clearance and zero preload; they are not a substitute for an application-specific contact-geometry limit.

For a pure axial example, the common static-equivalent-load expression gives P₀ = 0.5 Fₐ when Fᵣ = 0. With the SKF 6205 C₀ value of 7.8 kN, an illustrative Fₐ = 3.0 kN produces P₀ = 1.5 kN and C₀ / P₀ = 5.2. That arithmetic describes the static-equivalent-load ratio only. NSK warns that the contact ellipse can still pass over the raceway shoulder below the P₀ limit. The example demonstrates why the third check is independent; it does not certify 3.0 kN as an allowable axial load for any 6205.

The sources are not numerically interchangeable. SKF gives a general pure-axial rule expressed as a fraction of C₀; NSK gives a geometry-based method and a 6205 curve that depends on initial contact angle; NTN gives a series-and-bore chart based on median CN clearance and representative values. Their different published forms do not establish a controlled cross-brand ranking or a universal maximum axial load. Do not average the results or select the largest number.

Selection, substitution and RFQ checks

  • State the exact original manufacturer, full 6205 designation, clearance class, seal or shield execution, cage and lubricant. A generic 6205 label does not identify the internal geometry used in an axial-load calculation.
  • Provide radial load Fᵣ, axial load Fₐ, load direction, whether the load reverses, peak magnitude, duty cycle, speed and operating temperature. Separate continuous operating load from transient or shock load.
  • Request three distinct outputs: dynamic equivalent load P and life basis; static equivalent load P₀ and static safety basis; allowable axial load Fₐ max and the contact-ellipse / raceway-shoulder criterion used.
  • Ask whether the allowable axial-load value assumes CN, C3 or another clearance; identify the initial contact angle or internal-design basis and whether the result applies to the exact sealed or open execution being quoted.
  • For NTN chart use, ask NTN Engineering to confirm the value for the exact size and clearance. The published chart is based on median CN clearance and representative values, not a guaranteed special-clearance result.
  • For a high axial-load application, if the exact 6205 allowable axial load cannot be substantiated, evaluate a bearing arrangement designed for higher axial capacity, such as an angular-contact pair, rather than increasing the static safety factor and assuming the shoulder issue has disappeared.
  • At receiving, verify the exact manufacturer and full bearing marking against the approved calculation and drawing. A same-size substitute or a higher C₀ value alone is not evidence of equal allowable axial capacity.

Scope and limits: this section separates three calculation purposes for single-row deep-groove bearings and uses 6205 as the worked reference. The 3.9 kN value is derived only from SKF published C₀ = 7.8 kN and SKF pure-axial rule Fₐ ≤ 0.5 C₀. The 3.0 kN example is arithmetic only, not a design recommendation. NSK and NTN contact-ellipse methods require exact internal geometry or use representative chart assumptions; no exact batch-specific 6205 allowable axial-load certificate was found. The cited NTN chart is based on median CN clearance and must not be transferred to C3 or another special execution. No application load spectrum, mounting drawing, operating clearance, temperature distribution or manufacturer approval was supplied. This comparison identifies a missing mandatory check; it cannot approve a particular bearing or arrangement.

References: SKF, Loads — Single row deep groove ball bearings, Axial load carrying capacity and pure axial rule: SKF load guidance; SKF, 6205 product record, basic static load rating C₀ = 7.8 kN: SKF 6205 product record; NSK, Rolling Bearings for Industrial Machinery, CAT. No. E1103C, Part A, §4.7.1(2), printed pp. A 062–A 063, Fig. 4.24–4.25: NSK technical catalogue PDF; NTN, Ball and Roller Bearings, CAT. No. 2203-3/E, §17.3.1, printed pp. A-186–A-187, Fig. 17.3.1 and notes: NTN technical data PDF; Koyo / JTEKT, Basic Bearing Knowledge — Dynamic equivalent load, §5-4-1, single-row radial bearing formula and zero-clearance / zero-preload note: JTEKT dynamic equivalent load guidance.

6205 — matching bore, outside diameter and width do not guarantee the same shaft and housing shoulder fit

Buyer conclusion: four original-manufacturer records agree on the open 6205 envelope of 25 × 52 × 15 mm, but they do not publish one identical mounting envelope. SKF requires a larger minimum shaft shoulder and a smaller maximum housing shoulder than the corresponding published limits from NSK, Koyo / JTEKT and NTN / SNR. A shaft or housing machined to the less restrictive values can therefore be unsuitable for an SKF 6205 even though the bearing bore, outside diameter and width match. Check the actual shoulder and fillet dimensions against the exact maker before approving a replacement or reusing a machined seat.

Exact 6205 product-record comparison

Original manufacturer / exact open productBoundary dimensions d × D × BShaft shoulder daHousing shoulder DaFillet radius raBearing chamfer
SKF — 620525 × 52 × 15 mmmin. 30.6 mm; no maximum stated on the cited recordmax. 46.4 mmmax. 1 mmr1,2 min. 1 mm
NSK — 6205, open25 × 52 × 15 mmmin. 30 mm; max. 32 mmmax. 47 mmmax. 1 mmr min. 1 mm
Koyo / JTEKT — 6205, open25 × 52 × 15 mmmin. 30 mm; no maximum stated on the cited recordmax. 47 mmmax. 1 mmr min. 1 mm
NTN / SNR — 6205-SNR, open25 × 52 × 15 mmmin. 30 mm; no usable maximum stated (the page field is 0)max. 47 mmmax. 1 mmrs min. 1 mm

The difference that changes seat reuse

SKF lists da min. 30.6 mm, whereas NSK, JTEKT and NTN / SNR list da min. 30 mm. The difference is 0.6 mm on diameter, not a tolerance that can be ignored because the nominal bearing bore is the same. For example, a measured 30.2 mm shaft shoulder is above the published minimums of NSK, JTEKT and NTN / SNR, but below the SKF minimum. This is a geometry screen only; it does not establish that the shaft fit, shoulder face, load capacity or complete bearing execution is otherwise acceptable.

SKF also lists Da max. 46.4 mm, while the other three product records list 47 mm. A 46.8 mm housing shoulder is therefore above the SKF published maximum even though it is within the stated maximum for the other three records. The two 0.6 mm differences are diametral limits. They do not mean that the bearing boundary dimensions differ, and they do not prove a manufacturing defect in any product.

The public records do not give a complete common interval for every variable. NSK states a da maximum of 32 mm; SKF and JTEKT do not state a maximum in the cited 6205 record, and the NTN / SNR base 6205 page displays 0 in that field. A zero in that catalogue field is treated here as no usable upper limit, not as a physical zero-diameter allowance. Do not fill missing limits by copying another manufacturer value or by assuming the limits are identical.

Why the fillet and shoulder face still matter

All four cited 6205 records list a maximum shaft or housing fillet radius of 1 mm and a minimum bearing chamfer of 1 mm. These are limit values, not a measured clearance between the actual shaft corner and the actual bearing ring. NSK, JTEKT and NTN guidance states that the fillet must not interfere with the bearing chamfer; the shoulder face must be perpendicular to the shaft or housing axis, and the bearing ring needs proper support. A fillet that reaches the chamfer can prevent the ring from seating against the flat shoulder face. A poor shoulder face or insufficient support can compromise axial location and can distort the ring; it is not corrected by matching d, D and B alone.

JTEKT further explains that if a larger fillet is required, or the shoulder height cannot be achieved, a spacer may be needed. NTN describes a spacer for a fillet larger than the bearing chamfer or an abutment that is too low. Those are design remedies to be checked against the exact arrangement, not permission to machine an arbitrary spacer or to transfer one maker procedure to another.

RFQ, machining and receiving checks

  • State the exact manufacturer and complete 6205 designation, including clearance, seal or shield, cage and any retaining-ring execution. The table above is limited to the cited open standard 6205 records.
  • Put the shaft shoulder diameter da, housing shoulder diameter Da and fillet radius ra on the drawing as separate controlled dimensions. Compare each measured value with the exact offered manufacturer record.
  • Check shoulder height and end-face perpendicularity as well as diameter. The 6205 product records do not provide a common shoulder-height or support-width value, so obtain the maker drawing when axial load, axial location or limited face contact is important.
  • Check the actual bearing chamfer and the actual shaft / housing corner profile. Do not assume that two catalogue limits of 1 mm prove positive clearance in the assembled geometry.
  • If the shaft or housing needs a larger fillet, use a manufacturer-reviewed relief or spacer arrangement and confirm that the spacer supports the ring without touching the fillet.
  • At receiving, verify the exact ring marking and the supplier drawing revision. Catalogue limits are not a batch measurement or an inspection certificate.

Scope and limits: this comparison covers the cited open 6205 product records from SKF, NSK, Koyo / JTEKT and NTN / SNR. It does not extend automatically to sealed, shielded, snap-ring, high-temperature or other special 6205 executions. The product records do not disclose every upper/lower shoulder limit, shoulder height, support width, detailed chamfer profile or batch measurement. No shaft/housing drawing, axial load, fit, shoulder-face runout or measured corner profile was supplied. The comparison can reject an unverified seat reuse; it cannot approve a particular replacement, calculate axial capacity or guarantee operating clearance.

References: SKF, 6205 product record, dimensions and abutment dimensions: SKF 6205; NSK, 6205 Series product record, Boundary Dimensions and Abutment and Fillet Dimensions: NSK 6205; Koyo / JTEKT, 6205 product record, Specification Data and Mounting Dimensions: JTEKT 6205; NTN / SNR, 6205-SNR product record, Product Definition and Abutment: NTN / SNR 6205; SKF, Bearing Maintenance Handbook, PUB SR/P7 10001/1 EN, Basics, “Abutment and fillet dimensions”: SKF maintenance handbook PDF; NSK, Rolling Bearings for Industrial Machinery, §13.2 “Shoulder and Fillet Dimensions”: NSK catalogue PDF; Koyo / JTEKT, “Shaft and housing design”, shoulder face, fillet and spacer guidance: JTEKT shaft and housing design; NTN, Ball and Roller Bearings, CAT. No. 2203-3/E, §14.2.1 “Abutment height and fillet radius”: NTN shaft and housing design PDF.