An 811 or 812 designation is a cylindrical roller thrust bearing: the prefix tells the series and the last two digits carry the bore.

On the rows the collected tables cover, the 812 choice at a given bore runs a larger envelope and a higher axial rating than its 811 counterpart — at the 30 mm bore, 81206 is 52 by 16 at 50 kN against 81106 at 47 by 11 at 24.5 kN — and at the same 30 by 52 by 16 envelope as a 51206 ball thrust, the 81206 roller thrust carries about 1.8 times the dynamic and more than twice the static axial load while carrying no radial load at all.

The letters around the number name the parts: K is the roller-and-cage assembly, WS is the shaft-side washer, and GS is the housing-side washer.

The series prefix and the bore digits

A designation such as 81206 or 81110 starts with the series prefix — 811 or 812 — and the remaining two digits are the bore code. The catalogue rows show how the code maps to the shaft diameter.

Bore code 02 is 15 mm (81102), code 03 is 17 mm (81103), code 04 is 20 mm (81104) and code 05 is 25 mm (81105) in the Austin table7.

From code 06 onward the bore is five times the code: 81206 is 30 mm4, 81110 is 50 mm, and the largest row in the second-manufacturer tables, 81218, is 90 mm6.

So reading the number gives the series and the bore before any table is opened; the outer diameter, height and load ratings still need the catalogue row.

811 versus 812: same bore, different envelope and rating

Both series exist at the same bore, and the second digit selects the envelope.

At a 30 mm bore the Austin table lists 81106 at 47 mm outside diameter and 11 mm height with a dynamic axial rating of 24.5 kN, while 81206 occupies 52 mm by 16 mm with a dynamic rating of 50 kN7.

The NTN listing agrees on the 81206 envelope (30 by 52 by 16) and rates it at 53 kN dynamic with 129 kN static4.

The 812 section of the tables is also the fuller one: the second-manufacturer tables cover 81206 through 81218 without gaps456, while the 811 rows they carry run 81102 through 81117 and then jump to 81120 — no 81118 row appears in these tables75.

When a drawing gives only the bore, the choice between 811 and 812 is decided by the housing space and the axial load, not by the number itself.

Against a 511 or 512 ball thrust at the same envelope

The comparison that matters at purchase time is against the ball thrust bearings of the same bore.

The NTN pages make the envelopes directly comparable: the 51206 ball thrust is 30 by 52 by 16 — the same 30 by 52 by 16 as the 81206 roller thrust — yet its dynamic axial rating is just under 30 kN with a static rating of 58 kN, against 53 kN dynamic and 129 kN static for the roller version84.

In the same space, the cylindrical roller set carries roughly 1.8 times the dynamic and over twice the static axial load.

What the roller thrust gives up is direction: a single-direction cylindrical roller thrust is built to take axial load in one direction with no radial load carrying capacity, because its three components — a shaft washer, a housing washer and a roller-and-cage assembly — locate each other axially only7.

A ball thrust selection that also sees radial load, or reverses, is a different decision and needs its own row check.

K, WS and GS: which part is which

The letters around the number name the three separable parts. The JTEKT catalogue headings call K.811 and K.812 "thrust cylindrical roller and cage assemblies", and the washer tables pair each bearing with two washers: the shaft-piloted washer numbered WS and the housing-piloted washer numbered GS1.

The NTN shop pages name the same roles from the component side: WS is the washer riding the shaft (inner diameter 80 mm on the 81216 page) and GS is the housing-side supporting washer, with K81216 listed as the cage-assembly reference9.

The washer rows carry their own dimensions, which matter for seating: WS.81206 and GS.81206 run 30 by 52 at a thickness between 4.25 and 4.12 mm2, and the largest washer pair WS.81218 and GS.81218 runs 90 by 135 at up to 10.5 mm3.

When only the bearing number is on the drawing, the washer numbers follow mechanically — WS plus the same digits for the shaft side, GS plus the same digits for the housing side.

What to verify from a catalogue row when only the designation is known

With the number read, the row is what closes the purchase decision.

The checklist from the second-manufacturer tables: confirm the bore and envelope (d, D, height H) against the housing4; confirm the dynamic and static axial ratings against the applied load5; confirm the abutment diameters — the Austin rows carry shaft and housing abutment columns (d1, D1), for example 52 by 32 around the 81206 seat7; and where the supplier lists them, the minimum radius, reference and limiting speeds and the mass, which the Austin table carries for the 81206 to 81210 rows but the NTN listings for 81211 onward do not5.

Suffixes seen in the listings are part of this check too: the NTN row for the largest model reads 81218J6, so the exact suffix on the offer should be matched to the row actually quoted rather than assumed from the base number.

Before you request a quote

  • Public sources do not settle this — put it to the supplier: the meaning of the "J" suffix on the NTN 81218J listing row — the second-manufacturer sources list the suffix but do not define it; confirm the suffix definition with the manufacturer line before ordering against that row.
  • Public sources do not settle this — put it to the supplier: sealed or greased variants of the 811/812 designations (2RS, 2Z, ZZ): none of the three manufacturer tables collected here lists any such suffix on an 811xx or 812xx row, so this article cannot state whether they exist or what they would carry.
  • Ask for relevant export destinations, installed-base references and comparable customer contacts.
  • Public sources do not settle this — put it to the supplier: fatigue load limit and temperature limits for the series as a whole — the NTN shop pages carry them per item (for example on 51206 and 81216) but no source here covers the full series.
Sources · 9