# Slewing-bearing load case, bolted-joint and preload verification worksheet

> Controlled blank record. Complete one record per bearing installation and one row per governing load case. This worksheet is an evidence-capture aid, not a bolt-design method, structural calculation, tightening procedure or acceptance specification. Use the exact bearing manufacturer's current drawing/IOM, machine design basis, fastener supplier data and approved engineering calculation. Do not infer missing values.

## 1. Record identity and design authority

| Field | Entry |
|---|---|
| Project / machine / asset ID | |
| Bearing manufacturer / exact designation / execution | |
| Bearing serial / batch / ring orientation | |
| Bearing drawing number / revision / date | |
| Machine assembly drawing / revision | |
| Fixed support drawing / revision | |
| Rotating support drawing / revision | |
| Structural calculation / FEA ID and revision | |
| Bolted-joint calculation ID and revision | |
| Fastener specification / supplier / lot | |
| Applicable manufacturer IOM / catalogue revision | |
| Applicable customer / statutory / industry design basis | |
| Design authority / checker / approver | |
| Worksheet revision / date / prepared by | |

**Hold point:** identify who owns the bearing rating check, fastener/joint design, support-structure design and acceptance decision. A bearing catalogue curve is not approval of the machine's bolted joint.

## 2. Installation arrangement and load path

Select and sketch the actual arrangement; do not infer it from a product family name.

| Item | Record |
|---|---|
| Supported or suspended arrangement | |
| Axial load direction relative to fixing screws | |
| Which ring is fixed to which structure | |
| Fixed-side and rotating-side clamp interfaces | |
| Compression / tension / reversing load path | |
| Ring support and flange contact regions | |
| Bolt circle(s), pilot/centring and locating features | |
| Through-bolts, tapped holes, studs or other fastening | |
| Gearless / internal gear / external gear | |
| Drive reaction path into bracket and machine frame | |
| Sketch / section / load-path drawing reference | |

Attach a section view showing the bearing, both mating flanges, bolt rows, pilot features, structural shell/webs/gussets, load application point and gear-drive bracket. Mark the supported versus suspended side and positive directions for all loads.

## 3. Governing load-case register

Use one row for every simultaneous operating or exceptional condition. Do not combine independent maxima unless the design basis says they occur together. State whether each value is measured, calculated, specified or estimated.

| Case ID | State / event | Axial force Fa (kN) | Radial force Fr (kN) | Tilting moment Mk (kN·m) | Drive reaction / tangential force | Direction / sign / angle | Duration / cycles / frequency | Source and revision |
|---|---|---:|---:|---:|---|---|---|---|
| LC-01 | Normal duty | | | | | | | |
| LC-02 | Maximum operating | | | | | | | |
| LC-03 | Start / stop / reversal | | | | | | | |
| LC-04 | Braking / emergency stop | | | | | | | |
| LC-05 | Wind / environmental | | | | | | | |
| LC-06 | Impact / shock / jam | | | | | | | |
| LC-07 | Proof / overload test | | | | | | | |
| LC-08 | Assembly / lifting / transport | | | | | | | |
| LC-09 | Maintenance / disassembly | | | | | | | |
| LC-10 | Other governing case | | | | | | | |

For each case attach the load derivation, coordinate origin, force application point, sign convention, load combinations and any dynamic/amplification factors. Record the design-life spectrum separately; a single maximum static case does not establish fatigue adequacy.

## 4. Bearing-level checks — keep separate from joint checks

| Check | Method / manufacturer document | Case(s) | Inputs and factors | Result / curve point | Status / approver |
|---|---|---|---|---|---|
| Static raceway capacity | | | | | |
| Static fixing-screw capacity | | | | | |
| Dynamic raceway life | | | | | |
| Dynamic fixing-screw fatigue | | | | | |
| Radial displacement / friction-locking check | | | | | |
| Gear tooth / pinion capacity | | | | | |
| Manufacturer review for non-standard load arrangement | | | | | |

A successful raceway check does not establish fixing-screw adequacy. A fixing-screw curve does not replace the structural flange, bolt-group, thread engagement, local bearing/contact-pressure or fatigue checks. Record the exact bearing designation and curve/table reference used.

## 5. Fastener and threaded-joint definition

| Field | Entry |
|---|---|
| Fastener standard and edition | |
| Property/class/grade and manufacturer marking | |
| Nominal diameter / pitch / thread series | |
| Tensile stress area / proof strength source | |
| Fastener material / coating / plating | |
| Head / nut / washer type and hardness | |
| Grip length and clamped stack thickness | |
| Thread engagement length and engaged material | |
| Internal thread class / tapped component material | |
| Through-bolt or tapped-hole arrangement | |
| Number of fasteners and angular spacing | |
| Bolt-circle diameter(s) and actual hole coordinates | |
| Edge distance / local flange thickness | |
| Joint friction surfaces / coatings / lubricant | |
| Fastener lot traceability and certificate | |

Attach the actual fastener schedule and a clocked bolt-position map. Do not treat a catalogue hole count or nominal bolt diameter as a complete bolt specification. Confirm thread engagement and internal-thread stripping capacity in the actual mating material.

## 6. Preload design basis and installation method

| Field | Entry |
|---|---|
| Required target preload per fastener | |
| Minimum / maximum permitted preload and source | |
| Basis: OEM table, joint calculation or approved specification | |
| Tightening method: torque / angle / hydraulic / elongation / other | |
| Tool ID, range, calibration date and uncertainty | |
| Lubricant / coating / friction condition assumed | |
| Tightening factor / scatter model and source | |
| Tightening sequence and number of passes | |
| Seating / embedment / relaxation allowance and basis | |
| Re-tightening or retensioning requirement and source | |
| Direct preload measurement method, if used | |
| Acceptance authority and approved procedure revision | |

Record the method actually used, not merely the target torque. Torque is an indirect proxy for preload and depends on the stated friction condition. Do not transfer tightening torques or preload tables between manufacturers, fastener standards, coatings, lubricants or joint geometries.

### Individual fastener installation log

| Bolt ID / clock position | Fastener lot / grade | Tool ID | Lubricant / surface condition | Pass 1 | Final applied value | Direct elongation / preload reading | Timestamp / operator | Deviation |
|---|---|---|---|---:|---:|---:|---|---|
| B01 | | | | | | | | |
| B02 | | | | | | | | |
| B03 | | | | | | | | |
| B04 | | | | | | | | |
| B05 | | | | | | | | |
| B06 | | | | | | | | |
| B07 | | | | | | | | |
| B08 | | | | | | | | |
| Add rows for every fastener; do not sample a subset unless the approved procedure explicitly permits it. | | | | | | | | |

## 7. Joint and support calculation return

Request the calculation model and assumptions, not only a single maximum bolt-load number.

| Required output | Supplier / designer return |
|---|---|
| Model type and revision; hand calculation / beam model / FEA | |
| Element/contact assumptions and boundary conditions | |
| Flange, shell, web and gusset geometry/material inputs | |
| Contact-face condition, friction and separation assumptions | |
| Bolt stiffness, grip length, preload and stiffness interaction | |
| Bolt-group load distribution by bolt ID and governing case | |
| Maximum bolt tension / shear / combined stress and location | |
| Joint separation / contact-pressure distribution | |
| Local flange bending, prying and thread engagement checks | |
| Fatigue range, cycle count and governing spectrum | |
| Sensitivity to preload scatter, friction and support stiffness | |
| Mesh / convergence / validation or hand-check reference | |
| Design factors, acceptance criteria and approving engineer | |

**Do not reverse-engineer a general design rule from a manufacturer example.** Kaydon Catalog 390 printed p.33 describes its bolt-load equation as an approximate initial-sizing aid, states there is no universally accepted moment-loaded joint method, assigns bolt arrangement/quantity/size/thread engagement to the equipment designer, and strongly recommends testing to establish actual load. Its flexibility factor of 3 is specifically stated for average-stiffness bearing/support structures. It is not a universal coefficient or a substitute for the actual structure model.

## 8. Verification test and instrumentation plan

Define the approved test before loading. Do not create a proof load, overload percentage, load step, dwell time or acceptance threshold from this worksheet.

| Field | Entry |
|---|---|
| Approved test procedure / revision / authority | |
| Test configuration and installed boundary conditions | |
| Governing simultaneous load case(s) | |
| Load application equipment / calibration | |
| Load cell / pressure / torque sensor IDs and calibration | |
| Bolt elongation / preload measurement instrument and method | |
| Displacement sensor IDs, range, resolution and uncertainty | |
| Sensor coordinates, orientation and datum map | |
| Sampling rate / synchronization / data file ID | |
| Safety controls, exclusion zone and stop criteria | |
| Baseline and environmental conditions | |

### Load / response trace

| Test ID | Load step ID | Applied Fa / Fr / Mk / drive reaction | Load direction | Bolt ID / sensor point | Initial reading | Loaded reading | Unloaded return | Residual / hysteresis | Time / data file |
|---|---|---|---|---|---:|---:|---:|---:|---|
| | | | | | | | | | |
| | | | | | | | | | |
| | | | | | | | | | |

Capture the full load and unload trace. Record bolt elongation or other direct preload indicator where the approved method provides it; record support displacement at defined coordinates. A torque wrench click or applied torque value alone is not a direct measurement of retained bolt preload.

## 9. Post-test inspection and comparison

| Item | Before test | After test | Difference / trend | Acceptance source / disposition |
|---|---|---|---|---|
| Bolt preload / elongation by bolt ID | | | | |
| Witness marks / rotation / loosening | | | | |
| Joint opening / contact evidence | | | | |
| Flange permanent set / residual displacement | | | | |
| Cracks / fretting / coating damage | | | | |
| Thread / washer / bearing-face condition | | | | |
| Mounting-face geometry / runout | | | | |
| Raceway / tilting-clearance baseline, if required | | | | |
| Gear mesh / backlash / contact / pinion alignment | | | | |
| Deviations, corrective action and retest | | | | |

Any retorque, replacement, re-machining or rework must be linked to an approved disposition and new traceable record. Do not silently overwrite the original readings.

## 10. Manufacturer-specific method boundary register

| Source / document | What it supports | Conditions / limits to preserve | What it does not authorize |
|---|---|---|---|
| Kaydon Catalog 390, printed p.33 | Approximate initial estimate of the most heavily loaded bolt; load sign convention; proof-load comparison | Equation uses moment, bolt-circle diameter, evenly distributed bolt count and a flexibility factor; factor 3 is stated for average-stiffness structures | Universal bolt-group design, bolt size/thread engagement selection, actual bolt load or acceptance without application-specific design and testing |
| Schaeffler INA Catalogue 404, printed pp.20–21 | INA static/dynamic fixing-screw curve checks and stated installation prerequisites | Supported load arrangement; screws tightened as specified; 10.9 grade curve basis at 90% proof stress including torsion; grade conversion factors and radial guide values remain within this catalogue method | Direct transfer to another bearing brand, non-standard suspended arrangement, different tightening state or an unapproved machine joint |
| Schaeffler INA Catalogue 404, printed p.46 | Catalogue torque and fitting-preload tables for listed screw sizes/classes | Table footnotes state friction assumptions; use only with the applicable INA fitting instructions and exact fastener/joint conditions | Generic torque-to-preload conversion or substitution for a different lubricant, coating, washer, thread or joint |

When a source edition, page, figure or current applicability cannot be confirmed, mark it “not verified” and request the current manufacturer document. Record any written OEM engineering response with date, contact/reference and affected designation.

## 11. Decision and handover

| Gate | Evidence required | Result / reference | Owner / date |
|---|---|---|---|
| Load cases approved and traceable | | | |
| Bearing raceway and screw checks complete | | | |
| Structural and bolted-joint calculations approved | | | |
| Fastener specification and thread engagement approved | | | |
| Preload method and tools approved | | | |
| Installation log complete and deviations closed | | | |
| Test plan and instrumentation approved | | | |
| Test traces and post-test inspection reviewed | | | |
| OEM / designer written dispositions received | | | |
| Final acceptance and as-built record released | | | |

**Open items / exclusions:** 

**Design authority signature / date:** 

**Independent checker signature / date:** 

**Customer / OEM acceptance reference:** 

---

## Evidence and interpretation notes

1. A supported versus suspended arrangement changes the axial-load path through the fixing screws. Confirm the real arrangement from the assembly section and bearing-maker guidance.
2. Raceway capacity, fixing-screw capacity, adjacent support stiffness, fastener/thread capacity and gear-drive bracket stiffness are distinct checks. Passing one does not imply passing the others.
3. Bolt count and bolt-circle diameter alone do not define bolt load distribution. Joint stiffness, flange flexibility, contact, preload, geometry, friction, local bending and load direction matter.
4. A calculated bolt load is not a measured bolt load. State model assumptions and uncertainty; use an approved test when actual load or preload distribution must be established.
5. No universal bolt grade, preload percentage, tightening torque, safety factor, proof-load case, joint-separation limit or retightening interval is supplied here.